Product Description
C220 / C300 / C400
12
Service Instructions
03.22
2.2 Sensors
The contact of the pad onto the product or the reaching of the release
position is detected by a Hall-sensor. For which purpose the
displacement of the adapter bolt in relation to the sensor is used.
The start position is the upper end position of cylinder and the position
of the pad which takeover the label from printer. This position will be
detected via a Hall-sensor in interaction with a magnet mounted inside
cylinder.
The correct transfer of a label will be checked by the vacuum sensor.
It also checks that there is no longer a label on the pad in case the
return movement. This sensor is integrated to the applicator PCB.
The pressure sensor controls the pressure air. This sensor is
integrated to the applicator PCB.
Sensor labelling
position
Sensor start
position
Sensor vacuum
Sensor pressure
Содержание C220
Страница 1: ......
Страница 4: ...Table of Contents C220 C300 C400 4 Service Instructions 03 22 ...
Страница 8: ...Introduction C220 C300 C400 8 Service Instructions 03 22 ...
Страница 16: ...Product Description C220 C300 C400 16 Service Instructions 03 22 ...
Страница 26: ......
Страница 32: ...Troubleshooting C220 C300 C400 32 Service Instructions 03 22 ...
Страница 34: ...Block Diagram C220 C300 C400 34 Service Instructions 03 22 ...
Страница 36: ...Pneumatic plan C220 C300 C400 36 Service Instructions 03 22 ...
Страница 38: ...Terminal Diagram of PCB C220 C300 C400 38 Service Instructions 03 22 Figure 20 ...
Страница 40: ...Environmentally Friendly Disposal C220 C300 C400 40 Service Instructions 03 22 ...
Страница 43: ......
Страница 44: ......