•  Ensure that the cover is entirely dry before commissioning it.

•  Do not wash the foam supports.

• 

If the mattress is used in violation of the instructions specified in the user’s guide, 

or it is not cleaned of body secretions containing urea in particular, or the mattress 

system is used by a prominently sweating or mobile patient, the estimated life cycle 

of the cover and the cells may be shortened.

•  Do not store anything on top of the mattress system.

•  Do not place sharp or heavy objects on or near the mattress system. 

•  Keep the controller away from heat sources.

•  Avoid using the controller in the proximity of other electric devices or in a stacked 

configuration, as this may interfere with the controller’s operation. If the above use 

is necessary, ensure the normal operation of the controller by monitoring it.

 

• 

Using accessories, transformers or cables other than those specified by the manufac

-

turer or supplied with the device may result in elevated electromagnetic emissions 

or reduced electromagnetic immunity and have adverse effect on the performance 

of the controller for its intended purpose.

•  The distance of portable devices communicating using radio frequencies (including 

antenna cables and external antennas) to the controller and its cables should be at 

least 30 cm so as to ensure the performance specified in the technical files of the 

controller. 

•  The controller is intended for long-term use. However, it contains components that 

may break if the product is dropped or subjected to impact or vibration exceeding 

design standards. The limited manufacturer warranty does not apply to situations 

where the product has been mishandled.

•  The batteries may only be replaced by Carital

®

 service. Incorrect battery replace-

ment may result in a situation where the device will not work correctly.

•  Contaminated components must be cleaned before disposal or, if cleaning is not pos-

sible, disposed of in accordance with official regulations pertaining to contaminated 

healthcare waste.

• 

If  the  controller  has  encountered  a  significant  mechanical  strain  (dropped,  hard 

collision or similar), check the mechanical condition of the control port's connection 

gates and ensure that the seals between the operator panel/frame and the connec-

tion port/base plastic parts and the body are in place. If you notice any damage to 

the device, contact Carital

®

 service. 

•  Maintenance and repair must always be carried out by Carital

®

 service. The user is 

responsible for any and all consequences of the use of the device in a manner incon-

sistent with its intended purpose or resulting from maintenance, repair or modifica

-

Содержание OptimaCot

Страница 1: ...1 KOHJ H 15 EN1 1 0 15102021 User s guide OptimaCot...

Страница 2: ...dd on for the Medicase hygiene cover 12 3 3 Taking off the cover 12 3 4 Putting on the cover 13 4 Commissioning 16 4 1 Components of the mattress system 16 4 2 Connecting the mattress system to the be...

Страница 3: ...e and storage 38 7 1 Cleaning 38 7 1 1 Controller and tube system 38 7 1 2 Cells 38 7 1 3 Medicase cover 38 7 1 4 Comfort add on for the cover 39 7 1 5 Foam inserts for the cover 39 7 2 Checking the o...

Страница 4: ...745 MDR Main fuse infor mation Keep protected from rain Fragile handle with care Do not use if the packaging is damaged or has been opened Store away from heat See user s guide Type BF device Permitte...

Страница 5: ...signals and the adjustment of different adjustment regions Operating modes Normal operation Sitting operation Other NFC tag location in device note this feature is not yet implemented Keypad lock Bat...

Страница 6: ...ed with patients with lower ex tremities amputated from the midline of the legs upwards 2 5 System description The Carital OptimaCot mattress system has a double cell structure where the tun nel shape...

Страница 7: ...umber beginning with the PC iden tifier Only healthcare professionals can assess the need for and suitability of a mattress system in the treatment situation Any serious incident that has occurred in...

Страница 8: ...ead may result in suffocation Make sure that the air tubes and the controller s power cable cannot twist around the head or neck Place the controller s power cable in such a way that it cannot be clam...

Страница 9: ...reduction capacity is reduced Supine operation is used only for the treatment of immobile patients on horizontal position lying on their backs Selecting Supine operation in other treatment posi tions...

Страница 10: ...tenna cables and external antennas to the controller and its cables should be at least 30 cm so as to ensure the performance specified in the technical files of the controller The controller is intend...

Страница 11: ...se hygiene cover The Medicase hygiene cover protects the mattress system s cells from liquids and body fluids The surface of the cover is polyurethane and the lower layer is polyester The cover can be...

Страница 12: ...s from the controller 2 Pull down the tube sleeve to expose the by disconnecting the air tube system and air tube connectors Disconnect the air power cable Disconnect the power cable tubing from the c...

Страница 13: ...cover 3 4 Putting on the cover 1 If the cover has foam inserts place them 2 Insert the foam inserts into their desig on top of the cover Ensure that the label nated compartments in the cover Close in...

Страница 14: ...ide the upper cells first cell fastener adapter 7 Pass the strap through the lock and close 8 Pass the strap through its hole under the the lock foam insert 9 Pass the strap through the hole in the 10...

Страница 15: ...cord through the con duit in the cover 15 Pass the air tubing through its own tube sleeve Attach the air tubing to the cell s air tube system 12 Pass the tube sleeve over the air tubing 14 Pull the po...

Страница 16: ...e mattress system Controller Controller Type plate stickers on the side and at the bot tom of the controller contain the device iden tification information The lockable power cable 5 m The power cable...

Страница 17: ...es an example of troubleshooting The double sided quick guide is found on the back of the controller and is released for viewing by raising it upwards Be sure to put the quick guide caddy back in plac...

Страница 18: ...e gaps in the lying surface an extra bottom support foam optional accessory can be used inside the cover underneath the cells The support surface should fit the bed so that it does not extend over the...

Страница 19: ...o the moving back part of the lying surface not to the fixed part of the bed body Do not use extra bed sheets pillows or heavy positioning pillows on the mattress If side rails are used with the Carit...

Страница 20: ...ctive tube sleeve as far up as possible towards the controller 1 Suspend the controller at the end of the bed in as central position as possible 3 Make sure that the tube sleeve and power cord are as...

Страница 21: ...r As a general rule lift and handle the controller using two hands on both sides of the body or according to the instructions with the attached suspender 7 Plug the power cable into an electrical outl...

Страница 22: ...ube sleeve has been routed in the bed structure in such a way that it cannot be clamped by the folding parts of the bed Ensure that the label indicating the correct direction of installation of the ma...

Страница 23: ...size of the patient such that the pressure in all the adjustment sections are optimally placed to be regulated by the controller in correspond ence to the patient s body parts Make sure that the cont...

Страница 24: ...f the controller To turn off the controller in any operating mode press the device s standby button The controller can be turned off in any operating mode by pressing the de vice s standby button The...

Страница 25: ...tch to Sitting oper ation The device will first adjust the torso then the foot region and finally the head The Sitting operation LED is lit and the cell LEDs will move up or down The device has activa...

Страница 26: ...hanged This allows the controller to monitor the pressure in the torso cells If the pressure values of the torso cells are continuously outside the permissible limit values for 45 minutes the device w...

Страница 27: ...s function With the device in operation press the Supine operation button to activate the function The device activates Supine operation The device will first adjust the torso then the foot region and...

Страница 28: ...Once the patient transport is finished connect the controller back to the mains by connecting the power cable to an electrical outlet The cells will not deflate during transport The controller must be...

Страница 29: ...he cell s tube system and the power cable from the controller turn off the controller and contact Carital service 6 Information signals If the controller detects a failure or wishes to inform the user...

Страница 30: ...nowledge the failure indication signal press the information signal re set button Only the audible part of the information signal is acknowledged The visual information signals will remain on and the...

Страница 31: ...er 6 3 Check the air tubes leak in tube or inner cells The information signal reset button blinks and the display reads Check the air tubes See the removable quick guide This information signal is dis...

Страница 32: ...e Close the tube sleeve When you have checked the above ac knowledge the information signal by pressing and holding down the informa tion signal reset button for three sec onds If the information sign...

Страница 33: ...limit for scheduled maintenance is approaching prepare for maintenance Prepare to send the controller in for scheduled maintenance after one 1 month After this the device will display a re minder for...

Страница 34: ...hown in an illogical way Turn the controller off and on with the standby button shown in the figure The device will resume Normal operation af ter restarting If the device does not resume Normal op er...

Страница 35: ...t resume previous operation Immediately contact Carital service 6 9 Battery charge falls low When the charge of the internal battery falls to a very low level 7 2V 7 0V the controller will provide an...

Страница 36: ...isconnected from the mains before an ade quate charge level has been reached the device will shut down itself after 5 seconds after booting To maintain battery performance connect the controller to AC...

Страница 37: ...t by a party other than Carital service If the mattress system behaves contrary to the functions and situa tions described in this user s guide disconnect the air tubing from the cell s tube system an...

Страница 38: ...ediately if exposed to urea 7 1 1 Controller and tube system Disinfect by wiping using regular cleaning and disinfection agents including ethanol solu tions 60 80 chlorine solutions max 1 000 ppm Dry...

Страница 39: ...umble dry Do not iron Do not dry wash Do not use conditioners Ensure that the cover is entirely dry before commissioning it 7 1 5 Foam inserts for the cover Remove the integrated foam inserts from the...

Страница 40: ...e 7 2 3 Cells The condition of cells must be inspected When cleaning If you suspect that the cover is broken or the interior is contaminated When the patient changes or weekly in long term care Strip...

Страница 41: ...is used in violation of the instructions specified in the user s guide or it is not cleaned of body secretions containing urea in particular or the mattress system is used by a prominently sweating or...

Страница 42: ...Service To change from one tab to another in the maintenance view press the information signal reset button To return from the maintenance view to the normal operating mode press and hold down the in...

Страница 43: ...o 50 C 35 C to 70 C with vapour pressure 50 hPa Air humidity max 90 Store in a clean and dry place The cells and the cover can be rolled up for storage using for example the trans port bag accessory A...

Страница 44: ...an be recycled with cardboard The styrofoam packaging supports and packaging plastic can be recycled with plastic packaging 9 Warranty The Carital OptimaCot mattress system has three year warranty 36...

Страница 45: ...e Lithium ion 7 26V capacity 2 650mAh manufacturer Cell tech Oy Varta Storage GmbH Non rechargeable battery type CR2032 lithium ion 3 0V capacity 230mAh manufacturer Varta Microbattery GmbH Fuses F1 F...

Страница 46: ...014 IEC 60601 1 6 2010 IEC 60601 1 6 2010 AMD1 2013 IEC 60601 1 11 2015 IEC 62304 2006 IEC 62304 2006 AMD1 2015 IEC 62366 2007 IEC 62366 2007 AMD1 2014 IEC 60601 2 52 2009 subclause 201 9 101 EN ISO 1...

Страница 47: ...5 EN1 1 0 15102021 11 Contact details of the manufacturer and service Manufactured by MediMattress Ltd Haukilahdenkatu 4 FI 00550 HELSINKI tel 358 306 40 40 40 info medimattress fi Service add local s...

Страница 48: ...phase at 0 0 UT 250 300 cycle 0 UT 0 5 cycle at 0 45 90 135 180 225 270 and 315 0 UT 1 cycle 70 UT 25 30 cycles Single phase at 0 0 UT 250 300 cycle Mains power quality should be that of a typical com...

Отзывы: