ENG
3. Assembly
3.1
Preliminary
operations
3.1.1 Removing the cover
For steam blower installation or maintenance, remove the cover from the appliance as described below:
1. Disconnect the blower from the power supply;
2. Unscrew the two fixing screws placed on the top of the cover;
3. Pull the cover up by slightly turning it forward to release it.
Fig.3.a
3.2
Assembly
3.2.1 Mounting on top of the humidifier
Important:
install the humidifier in a horizontal position using a spirit level.
Procedure:
1. Remove the cover from the blower and the front and top of the humidifier;
2. Remove the caps (1) and (2) on the humidifier top panel;
3. Cut the steam hose (3) supplied to the right length and connect it to the fitting (4). To secure it,
tighten the metal clamps (5) using a screwdriver;
4. Insert the condensate drain hose (6) to the fittings on the blower and the humidifier panel. To secure
it, tighten the metal clamps (7);
5. Connect the two-wire cable (≥1mm2, Lmax = 4 m) from the humidifier to the blower. The terminals
(9) are located in the humidifier electrical panel;
6. Make the electrical connections as specified in "Wiring diagram".
7. Mount the blower on the humidifier;
8. Insert the fixing screws (10);
9. Place the cover back on the blower.
12
| 3. Assembly
VSDU0A0003
+030222190
rel.
1.4 – 11.02.2021