Effect
Buzzer LED Priority
Delay
(s)
No. of
activat.
Evaluation
period (s)
A20
Overcurrent
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A21
HW overcurrent
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A22
Overcurrent rms
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A23
Current measure-
ment error
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A24
Unbalanced com-
pressor currents
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A25
Overvoltage
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A26
Undervoltage
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A27
DC bus ripple
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A28
DC bus voltage
out-of-range
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A29
DC bus voltage
measur. error
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A30
Power overload
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A31
Input voltage out
of range
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A32
Power supply
voltage acquisition
error
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A33
Compressor stall
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A34
Low cosphi
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A35
STO line open
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Serious
0
5
3600
A36
STO fault
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Serious
0
5
3600
A37
CPU error
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A38
CRC error on
parameters
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A39
CRC error on
parameters
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A40
Reference voltage
not valid
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A41
Overtemperature
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A42
Undertemperature Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A43
Thermistor fault
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A44
Serial communica-
tion timeout
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A45
Default parameters Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A46
Unexpected stop
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Normal
0
5
3600
A47
Drive offline
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Serious
0
5
3600
A48
Digital output
configur. error
Semi-auto
Compressor off. Up to five restart attempts
without considering the timers
9
9
Serious
0
5
3600