background image

8200-M535-O1 Rev B 

 225-DS 

TABLE OF CONTENTS 

INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 1 
SPECIFICATIONS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 2 
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 3 

Load Cell Cable Connection with RFI Suppression  . . . . . . . . . . . . . . . . . . . . . . .  Page 6 
Load Cell Cable Connection without RFI Suppression  . . . . . . . . . . . . . . . . . . . .  Page 9 
Load Cell Cable Connections with Over 30 Feet of Cable . . . . . . . . . . . . . . . . . .  Page 9 
Sense Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 10 
Dead Load Boost Jumper (DLB) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 10 
Gnd to Chassis Jumper  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 10 

INDICATOR SETUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 11 
CALIBRATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 13 
MULTI-SCALE OPERATION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  Page 14 

 

FCC COMPLIANCE STATEMENT 

This equipment generates uses and can radiate radio frequency and if not installed and used 
in accordance with the instruction manual, may cause interference to radio communications.  It 
has been tested and found to comply with the limits for a Class A computing device pursuant 
to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection 
against such interference when operated in a commercial environment.  Operation of this 
equipment in a residential area may cause interference in which case the user will be 
responsible to take whatever measures necessary to correct the interference. 

 

You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” prepared by the 
Federal Communications Commission helpful.  It is available from the U.S. Government Printing Office, 
Washington, D.C. 20402, Stock No. 001-000-00315-4. 

 

All rights reserved.  Reproduction or use, without expressed written permission, of editorial or 
pictorial content, in any manner, is prohibited.  No patent liability is assumed with respect to 
the use of the information contained herein.  
 
 While every precaution has been taken in the preparation of this manual, the Seller assumes 
no responsibility for errors or omissions. Neither is any liability assumed for damages resulting 
from use of the information contained herein.  All instructions and diagrams have been 
checked for accuracy and ease of application; however, success and safety in working with 
tools depend to a great extent upon the individual accuracy, skill and caution.  For this reason 
the Seller is not able to guarantee the result of any procedure contained herein.  Nor can they 
assume responsibility for any damage to property or injury to persons occasioned from the 
procedures.  Persons engaging the procedures do so entirely at their own risk. 

PRECAUTIONS 

 

Before beginning installation of this option card, read this manual and pay 
special attention to all "WARNING" symbols: 

 

  

   

IMPORTANT

 

  

  

   

ELECTRICAL
WARNING 

 

 

  

   

STATIC 
SENSITVE 

 

 

II 

Содержание 225-DS

Страница 1: ...DS 225 Dual Scale Input Card Installation Manual 8200 M535 O1 Rev B 203 E Daugherty Webb City MO 64870 USA Printed in USA 10 09 Ph 417 673 4631 Fax 417 673 2153 www cardinalscale com Technical Support...

Страница 2: ...8200 M535 O1 Rev B 225 DS 2...

Страница 3: ...nd Resolve Radio TV Interference Problems prepared by the Federal Communications Commission helpful It is available from the U S Government Printing Office Washington D C 20402 Stock No 001 000 00315...

Страница 4: ...h or without totalizing with the use of the 225 DS without the need for complicated programming devices The 225 DS card resides in the 225 main enclosure and has a 16 pin dual in line Internal Bus con...

Страница 5: ...e Rate selectable 1 to 100 samples per second Auto Zero Range 0 5 divisions or 1 through 9 divisions Excitation Voltage 12 0VDC Signal Input Range 1 0 mV min to 40 mV max with dead load boost Load Cel...

Страница 6: ...are not to stretch the cable and wires between the panel and main housing Lay the back panel on the workbench next to the indicator IMPORTANT You may need to loosen the gland connectors for the scale...

Страница 7: ...6 32 threaded stud Reinstall the washer and 6 32 nut and tighten Refer to Figure No 3 NOTE Position the ring terminal with the wire extending away from the main board as shown to prevent shorting 8 T...

Страница 8: ...n the holes in the 225 DS with the threaded mounting spacers on the main board and using the four lock washers and screws supplied with the 225 DS secure the card to the main board Refer to Figure No...

Страница 9: ...s shown in Figure No 6 3 Loosen and remove the metal gland connector nut and remove the plastic insert 4 Referring to Figure No 7 route the single cable from the load cell or load cell junction box th...

Страница 10: ...ITATION SHLD SHIELD Not used the shield wire is connected to metal gland 9 To terminate a wire use a small flat blade screwdriver and press down on the release bar for the terminal Insert the wire int...

Страница 11: ...ck over the plastic insert and then insert the plastic insert with the shield wire into the gland connector Figure No 10 13 The shield wire is secured when tightening the gland connector nut See Figur...

Страница 12: ...P2 or P3 Refer to Figure No 12 for terminal block location Load Cell Wiring Table P2 or P3 Board Label Function Board Label Function EXC EXCITATION SIG SIGNAL SEN SENSE SEN SENSE SIG SIGNAL EXC EXCITA...

Страница 13: ...NS J4 jumpers on the 225 DS must be open on one pin only or removed Dead Load Boost Jumper DLB For very low dead loads less than 10 of the combined load cell capacity connect the dead load boost DLB j...

Страница 14: ...splayed press the 1 key and then the ENTER key The display will change to show SETUP MENU 1 SETUP MENU 1 1 USA XXX 6 CLR TARE XXX 2 NSC XXX 7 CLEAR ID XXX 3 LFT XXX 8 NO OF SCALES X 4 OIML XXX 9 TOTAL...

Страница 15: ...oft keys and then the ENTER key to save the new setting and return to SETUP MENU 1 10 MODE OF OP X XXXX MODE OF OPERATION IMPORTANT The Mode Of Op is limited to options 0 NORM Normal Indicator 1 IDS I...

Страница 16: ...or the setup of each scale IMPORTANT All scales to be included in the totalizer must have identical settings for BASE UNITS CNVT UNITS INTERVAL DDP SAMPLES STABLE and STBL CNT If these are not the sam...

Страница 17: ...and then that scale will become the active scale Zero the Scale with TOTALIZE NO Active Scale Press the ZERO key Only the active scale will be zeroed Zero Scale 1 Press the 1 key and then the ZERO key...

Страница 18: ...then the ZERO key Only Scale 2 Press the 2 key and then the ZERO key Only Scale 3 Press the 3 key and then the ZERO key IMPORTANT Note that the SCALE TOTALIZER cannot be manually zeroed It will only...

Страница 19: ...8200 M535 O1 Rev B 225 DS 16...

Страница 20: ...8200 M535 O1 Rev B 225 DS 17...

Отзывы: