PLS Series

Operation Manual

YCO-1101-05-02

YAMATO CORPORATION

1775 S. Murray Blvd.
Colorado Springs, CO  80916   USA
Tel (719) 591-1500  Fax (719) 591-1045

YAMATO TECH CORPORATION

#112-19425 Langley By-Pass
Surrey, B.C.  V3S 6K1     Canada
Tel (604) 533-2338  Fax (604) 533-0827

www.yamatocorp.com

Summary of Contents for PLS Series

Page 1: ... 05 02 YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 www yamatocorp com ...

Page 2: ...ay break or puncture the switch membrane panel 2 Use the specified power supply and choose a suitable environment If you do not the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the platform or drop it the scale may be damaged and lose accuracy 4 If the scale becomes dir...

Page 3: ... Weighing system Strain gauge load cell Platform 5 9 x 4 7 150 x 120 mm stainless steel Dimensions 6 7 D x 5 9 W x 1 5 H 170 x 150 x 38 mm Weight display Single face display Type 7 segment LCD Characters 0 8 H x 0 25 W 20 x 6 mm 5 digits Power supply 9 V alkaline battery or 9 VDC 100 mA AC adaptor Battery life 20 hours of continuous use Operating temperature 50 F to 95 F 10 C to 35 C Capacities an...

Page 4: ...at is se lected ON will be displayed in sequence when the key is pressed The auto off setting selects the duration in seconds after which the scale will automatically turn itself off if it is not being used If OFF is selected the auto off function will be disabled The capacity setting should only be changed if the load cell and front panel are being changed Calibrating the Scale With the scale on ...

Page 5: ...YCO 1101 05 02 PLS Series Operation Manual III Setup 3 Press for three seconds Return to normal weighing mode g g g g g g lb oz lb oz g g dwt dwt lb oz lb oz lb oz lb oz dwt ozt ozt ozt ...

Page 6: ...le Functions to change this feature Low Battery Condition The low battery indicator will appear when the battery needs to be replaced See section III Installing the Battery to replace the battery Zero the Display The scale will automatically zero when turned on If a value is displayed when the platform is empty push the key to zero the display The maximum zero range is approximately the capacity o...

Page 7: ...city of the scale 4 To return to gross weighing mode remove all items from the scale platform and press the key Batching 1 Begin with no load on the scale and the display reading zero 2 Place an empty container on the scale platform wait for a stable weight indication and press the key The weight of the container will be deducted automatically and the display will read zero 3 Place the first item ...

Page 8: ...y excessive nega tive reading 1 Place the scale platform back on the scale if it has been removed 2 Check to make sure nothing is wedged beneath the scale platform causing it to stick 3 Calibrate the scale 4 Have the scale serviced by a qualified scale technician The scale is reading a negative weight that is beyond the ability of the scale to display This usually occurs in pound and in pound ounc...