8200-M535-O1 Rev B
225-DS
11
INDICATOR SETUP
For additional information on setup and calibration, refer to the 225 WEIGHT
INDICATOR Installation and Technical Manual, 8200-M538-O1.
With the indicator ON, press the
SHIFT
key and then press the Navigation
ENTER
key (red
square key in center of the Navigation arrows). The display will change to show the
SETUP/REVIEW MENU.
SETUP/REVIEW MENU
1.ENTER CALIBRATION AND SETUP
2.VIEW AUDIT TRAIL COUNTERS
3.CALIBRATE SCALE 1
9.DEL CUSTOM TICKET
10.PRINT SETUP
Enter Selection: 1
^
EXIT
SETUP MENU #1
With the SETUP/REVIEW MENU displayed, press the
1
key and then the
ENTER
key. The
display will change to show SETUP MENU #1.
SETUP MENU #1
1. USA=XXX
6. CLR TARE=XXX
2. NSC=XXX
7. CLEAR ID=XXX
3. LFT=XXX
8. NO OF SCALES=X
4. OIML=XXX
9. TOTALIZE=XXX
5. TIME=XX
10. MODE OF OP=0 NORM
Enter Selection: 0
`
NEXT
^
EXIT
8. NO OF SCALES=X
(NUMBER OF SCALES)
With SETUP MENU #1 displayed, the current setting for the
NO OF SCALES=
parameter
will be shown. Note that X is the current value.
Press the
8
key, the
ENTER
key and then using the numeric keys, enter the number of
scales and then press the
ENTER
key to save the new setting and return to SETUP
MENU #1. Allowable values are: 1, 2 or 3. Note that the 225 will check for the 225-DS
card. If the card is not found, it will display an error message and default back to 1 scale.