8200-M554-O1 Rev C 2XX-EIP Installation and Setup Manual
6
225 INDICATOR SETUP, CONT.
SETUP MENU #3
1. G/N ACCUMS=XXX
6. KEY LOCKOUT
2. BACK LITE= X
7. LRPort=COM3
3. PASSWORD
4. 2XX-EIP/MODBUSTCP
5. BADGE RDR 10. Send Grs En=XXX
Enter Selection: 0
^
PREV
`
EXIT
With SETUP MENU #3 displayed, press the
4
key and then the
ENTER
key. The display will
change to show the
2XX-EIP/MODBUSTCP SETUP MENU
.
2XX-EIP/MODBUSTCP SETUP MENU
5. BYTEORDER = XXXX
Enter Selection: 0
^
EXIT
With 2XX-EIP/MODBUSTCP SETUP MENU displayed, the current setting for the
BYTEORDER =
parameter will be shown. Note that XXXX is the current setting for the byte
order. If the setting displayed is acceptable, press the Navigation
EXIT
arrow until the indicator
goes into the weight display mode.
Otherwise, press the
5
key, the
ENTER
key, and then using the numeric keys, enter the setting
for the byte order. Press the
ENTER
key to save the new setting and return to the
2XX-EIP/MODBUSTCP SETUP MENU. Allowable values are:
1234
4321
3412
2143
Default setting.
Press the Navigation
EXIT
arrow until the indicator goes into the weight display mode.
NODE ADDRESS SETUP
On an EtherNet/IP network,
each node must be assigned its
own unique TCP/IP address.
The 2XX-EIP EtherNet IP
interface card IP address is set
using the Anybus IPconfig Tool
Utility, available when logged
into the dealer-protected
software section of
CardinalScale.com. Download
the file from CardinalScale.com
by navigating to 225 Navigator
> Resource Type > Software >
2XX-EIP Anybus IPconfig Tool
Utility.
NOTE:
EtherNet/IP makes use of TCP port number 44818 for explicit messaging and UDP
port number 2222 for implicit messaging.
Double click on the highlighted module.
Change DHCP to a fixed IP address.