8200-M554-O1 Rev C 2XX-EIP Installation and Setup Manual
4
INSTALLATION, CONT.
Ethernet Cable Installation
1. Loosen an unused cable gland connector for the cable.
2. Insert the Ethernet cable (CAT 5 or equivalent) through the gland connector and into the
enclosure.
3. Consult your network administrator for the proper procedure to terminate the cable.
4. After the cable has been terminated, plug the cable into the RJ-45 jack on the 2XX-EIP.
Item #
Description
Item #
Description
1
Status LED’s
4
EtherNet/IP Module
2
Ethernet Connector
5
P2 Expansion Connector
3
P4 Connector (pins on trace
side of board)
6
Ground Wire
2XX-EIP Status LED’S
The 2XX-EIP EtherNet/IP Interface Card contains three LEDs to indicate the communication
status with the indicator mainboard.
CS, Chip Select
LK, Link
ML, Main Line
If the CS (Chip Select) LED is off, communications may
have been lost between the EtherNet IP module and the
indicator mainboard. Cycle power (press
ON/OFF
key
twice) to re-establish communications.
The LK (Link) LED displays the communication status.
It will be on or flashing rapidly when communications between the 2XX-EIP and the EtherNet
IP network are established.
The ML (Main Line) LED will be on to indicate the 2XX-EIP is powered up and running.
IMPORTANT: A load cell connection is required when testing the indicator.
An ERR AL or ERR AH condition will cause the communications from the
mainboard and the module to be very slow and will inhibit communications
with the EtherNet/IP module.
CS
ML
LK