8200-M554-O1 Rev C 2XX-EIP Installation and Setup Manual
12
205/210 COMMANDS
CMD0 and CMD1 combined to make the command word. Command words are broken into
command bits for PLC ease of programming. To invoke a command set the bit to one. The
PLC should continue to send a command until the command is returned by the indicator. If the
indicator cannot perform a command the returned command will include Bit7.
Bit00 GROSS/NET
Bit01 PRINT
Bit02 ZERO
Bit03 PB TARE
Bit04 KB TARE requires float point value be sent in Bytes 4, 5, 6, and 7
Bit05 not defined
Bit06 not defined
Bit07 This bit is the error bit from the 2XX when a command fails.
Bit08 PWC1 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit09 PWC2 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit10 PWC3 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit11 PWC4 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit12 PWC5 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit13 PWC6 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit14 PWC7 requires float point value be sent in Bytes 4, 5, 6, and 7
Bit15 PWC8 requires float point value be sent in Bytes 4, 5, 6, and 7