User Manual of HD-TVI Speed Dome
32
3.5.3
Configuring Alarm Output
Purpose:
An alarm output is a configurable alarm output interface on the speed dome back box which can
connect and trigger another alarm device to operate.
Steps:
1.
Enter the alarm output configuration submenu:
MAIN MENUS > DOME SETTINGS > ALARM OUTPUT
ALARM OUTPUT
ALARM OUTPUT 1 CLOSE
DWELL TIME 2
ALARM OUTPUT 2 OPEN
DWELL TIME 0
BACK EXIT
Figure 3-21
Configure the Alarm Output
2.
Click
IRIS+
to edit the status of the alarm outputs. You can set the alarm output type as
OPEN
(normally open) and
CLOSE
(normally closed).
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.
3.
Move the cursor to
DWELL TIME
to set the duration of the alarm output signal. The configurable
rage is 0~60 seconds.
4.
Link the alarm output to the configured alarm.
Steps:
(1)
Enter
MAIN MENUS > DOME SETTINGS > ALARM INPUT > ALARM SETTING
and choose the
alarm number that you want to link the alarm output to.
(2)
Move the cursor to
ALARM OUTPUT
and click
IRIS+
to configure the alarm output to the
alarm. You can choose
NONE
to disable alarm outputs, choose
1
to active ALARM OUTPUT
1.
There is 1 alarm output configurable; configuring the alarm output 2 will be invalid.