User Manual of HD-TVI Speed Dome
9
MAIN MENUS > SYSTEM INFO
SYS INFO
XX-XXXXX-X
ADDRESS 0
COM FORMAT 2400,8,1
PROTOCOL SELF ADAPTIVE
VERSION 1.00
HARDVERSION 1.00
BUILD DATE 13 04 01
BACK EXIT
SYS INFO
CAM VERSION X.XX
PARAM DATE X XX XX
TEMPERATURE 38
BACK EXIT
Figure 3-3
System Information
Information on this menu cannot be edited.
The temperature refers to the internal temperature of the speed dome.
3.2.2
Configuring System Parameters
Purpose:
You can check and also edit the system information of software address, baud rate, system time, etc.
on the system information settings menu.
MAIN MENUS > DOME SETTINGS > SYSTEM SETTINGS
SYSTEM SETTINGS
SOFT ADDRESS 1
SET SOFT ADDR OFF
SOFT BAUDRATE 2400
SET SOFT BAUD OFF
BROADCAST ADDR ON
PELCO CHECKSUM ON
SYSTEM TIME
BACK EXIT
SYSTEM SETTINGS
ANGLE ZERO
<DISPLAY SETTINGS>
HEAT CONTROL TEMP
FAN CONTROL TEMP
EIS SETTINGS OFF
EIS LEVEL N/A
PRESET FOCUS OFF
BACK EXIT
SYSTEM SETTINGS
PROTOCOL STATUS OFF
PROTOCOL AUTO MATCH
485 CHECK AUTO
MEMORY TIME 180S
COAXIAL CONTROL ON
PROTOCOL-C AUTO
BACK EXIT
Figure 3-4
System Information Settings
You can click the left and right direction buttons in the PTZ control panel via the web browser of
the encoding device (e.g. recorder) to enter the next page and return to the previous page of
the submenu if more than one page is available.
Dome address settings
To Set the Soft Address of the Speed Dome
If the
SET SOFT ADDR
is set as
ON
, the soft address is the valid address for connecting the speed
dome. The selectable soft address range is from 1 to 255;
Содержание Winic RedLine CT-AP313-IR