Before You Use the Product
12
Installing the Product
VC-C4
COMMUNICATIO
N CAMERA
VC-C4 Installation
Install in a flat and stable location.
VC-C4R Installation
Firmly tighten the 2 screws (not supplied).
Screw
VC-C4R
Mounting plate
(Installation)
• Distance between tapped holes: 114 mm (4
1
/
2
in.)
• Tapped hole diameter: 6 mm (
7
/
32
in.)
• Mounting plate thickness: 1 mm (
1
/
16
in.)
Screw
WARNING
Install the camera securely.
●
When installing the camera on the ceiling, contact your Canon dealer.
●
When installing the camera on the ceiling, check that the ceiling is strong enough to
bear the weight of the camera including the installation bracket. Installation in a weak
location could result in the camera falling and causing serious injury.
●
At least once a year, check for looseness in the camera installation mount. (If the
optional wide-angle converter is used, check the converter mount also.)
NOTE
The permissible camera installation angles are
±
20
°
from the horizontal. (
±
15
°
when the optional wide-angle converter is used.)
Using a Tripod
The screw mount for a tripod is located in the center of the underside of the camera.
NOTE
●
Do not overtighten the mounting screw.
If excessive force is used to tighten the
mounting screw, camera head movement may
be impeded, or other malfunctions may result.
●
Always use a tripod mounting screw that is less
than 6.0 mm (
1
/
4
in.) in length. The use of screws
6.0 mm (
1
/
4
in.) long or longer could damage
the camera. Also, the tripod seat used should
be at least 30 mm (1
3
/
16
in.) in diameter.
Mounting
screw
Less than
6.0 mm
(
1
/
4
in.)
30 mm
(1
3
/
16
in.)
or wider