Chapter 2: Service Error Codes
2-43
Cause
Remedy
##280
[
TX
] The number of re-transmissions of the
procedure signal has been exceeded
• Increase the transmission level
*1
so that the
other party may receive TCF correctly.
• Ask the other party to increase the trans-
mission level
*1
so that the appropriate sig-
nal may be received correctly.
• Using a manual call, press the Start button
after hearing the 1st DIS from the other
party.
• To prevent response to the 1st DIS from
the other party, put a relatively long pause
to the telephone number when registering
an auto-dialing number.
• Ask the operator of the other party to pro-
vide echo remedy 2
*7
.
• Ask the operator of the other party to de-
crease the transmission level
*1
so that the
other party will not receive an echo.
• Check to see that the telephone line is con-
nected correctly.
• Avoid disconnecting the telephone line
while a communication is under way.
• The line condition is poor, and the appro-
priate signal from the other party cannot
be received correctly after transmission of
TCF.
• The other party malfunctioned because of
an echo.
• The telephone line has a faulty connection.
• During a communication, the telephone
line was disconnected.
Содержание PowerShot G3
Страница 12: ...Introduction X This page intentionally left blank ...
Страница 13: ...Chapter 1 User Error Codes ...
Страница 58: ...Chapter1 User Error Codes 1 45 Cause Remedy Cause Remedy ...
Страница 59: ...Chapter1 User Error Codes 1 46 Cause Remedy Cause Remedy ...
Страница 60: ...Chapter 2 Service Error Codes ...
Страница 275: ...Chapter 2 Service Error Codes 2 215 Cause Remedy Cause Remedy ...
Страница 276: ...Chapter 2 Service Error Codes 2 216 Cause Remedy Cause Remedy ...
Страница 277: ...Appendix ...
Страница 310: ...0901 AT CANON INC ...