Chapter 2: Service Error Codes
2-19
Cause
Remedy
• Record the protocol on a DAT or MD, and
have it analyzed by the local Canon office
and/or Technical Center.
• The procedure signal is faulty.
Cause
Remedy
##114
[ RX ] RTN was transmitted
• Ask the operator of the other party to in-
crease the transmission level
*1
so that the
image signal may be received correctly.
• Ask the operator of the other party to de-
crease the transmission start speed.
• Adjust the NL equalizer
*2
so that the im-
age signal may be received correctly.
• Loosen the RTN transmission conditions
*6
so that RTN will not be transmitted.
• Provide echo remedy 3
*7
.
• Decrease the transmission level
*1
so that
an echo of transmitted CFR will not be re-
ceived.
• The line condition is poor, and the image
signal from the other party cannot be re-
ceived correctly.
• The machine malfunctioned because of an
echo of CFR.
##113
[
TX
] After transmitting Q or PRI-Q, a signal other
than MCF, RTP, RTN, PIP, or PIN was received
Содержание PowerShot G3