xx92
The value delta D obtained from the
result (Sig D) of computation based on
the reading of the patch during patch
detection is -5.0% or more 3 times
continuously.
The patch sensor may be damaged or
has an open circuit. The connector has
poor contact. The primary transfer
engagement is faulty. The mounting of
the developing assembly is faulty. The
amount of supply is low.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
xx93
The value delta D obtained from the
result (Sig D) of computation based on
the reading of the patch during patch
detection is +5.0% or lower 3 times
continuously.
The patch sensor is damaged or has an
open circuit. The connector has poor
contact. The primary transfer pressure
is faulty. The mounting of the
developing assembly is faulty. The
amount of supply is low.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
xxA0
For ATR control, the Sig value is lower
than 62.
The ATR sensor is damaged or has an
open circuit. The connector has poor
contact.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
xxA1
For ATR control, the Ref value is lower
than 62.
The ATR sensor is damaged or has an
open circuit. The connector has poor
contact.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
xxA2
For ATR control, the Sig value is 960 or
higher.
The ATR sensor is damaged or has an
open circuit. The connector has poor
contact. The opening/closing of the
shutter is faulty.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
xxA3
For ATR control, the Ref value is 960
or higher.
The ATR sensor is damaged or has an
open circuit. The connector has poor
contact.
Turn off and then on the main power;
then, execute the intermediate transfer
belt.
Code
Cause/Particulars of detection
Remarks
Содержание iR C6800 Series
Страница 1: ...Jan 20 2005 Portable Manual iR C6800 Series ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 13: ...Chapter 1 Maintenance and Inspection ...
Страница 14: ......
Страница 16: ......
Страница 20: ...Chapter 1 1 4 Under high humidity and high temperature condition 85 000 images ...
Страница 51: ...Chapter 2 Standards and Adjustments ...
Страница 52: ......
Страница 79: ...F 2 27 1 ...
Страница 99: ...F 2 88 F 2 89 1 OK NG NG ...
Страница 110: ......
Страница 111: ...Chapter 3 Error Code ...
Страница 112: ......
Страница 114: ......
Страница 172: ......
Страница 173: ...Chapter 4 User Mode Items ...
Страница 174: ......
Страница 176: ......
Страница 188: ...LIPS emulation 12 items utility printer initialize yes no Item Description ...
Страница 190: ......
Страница 191: ...Chapter 5 Service Mode ...
Страница 192: ......
Страница 380: ......
Страница 381: ...Chapter 6 Outline of Components ...
Страница 382: ......
Страница 384: ......
Страница 387: ...F 6 1 SL7 CL3 CL2 SL6 SL8 SL9 SL2 SL1 SL4 SL3 SL5 CL1 SL10 SL11 SL12 ...
Страница 393: ...F 6 3 M19 M32 M31 M30 M17 M14 M29 M6 M9 M10 M11 M12 M25 M13 M28 M20 M22 M21 M26 M27 M15 M2 M5 M4 M3 M8 M1 M18 M23 ...
Страница 397: ...F 6 5 FM2 FM10 FM11 FM12 FM6 FM3 FM4 FM8 FM9 FM5 FM7 FM1 ...
Страница 407: ...F 6 9 PS65 PS38 PS39 PS46 PS44 PS45 PS52 PS53 PS58 PS59 PS37 ...
Страница 413: ...LA1 J602 601 J206 Notation Main controller PCB Inverter PCB Reader controller PCB AC driver PCB DC controller PCB ...
Страница 417: ...F 6 13 13 2 5 3 14 15 16 9 6 12 7 1 11 4 25 24 21 23 19 20 31 29 28 27 26 22 18 17 32 30 10 8 ...
Страница 418: ......
Страница 419: ...Chapter 7 System Construction ...
Страница 420: ......
Страница 422: ......
Страница 443: ...Chapter 8 Upgrading ...
Страница 444: ......
Страница 446: ......
Страница 455: ...Jan 20 2005 ...
Страница 456: ......