87
9) Remove the 2 e-rings [1], and then replace the exchange flapper arm [2].
10) Mount the exchange flapper unit to be removed in the step 7).
11) In a state that the solenoid pin [1] is completely pulled in the arrow direction, check that the gap [a]
between the exchange flapper [2] and the metal plate guide [3] is 0.5mm. Regarding the method for
checking the gap, there is no problem if the JIS standard thickness gauge [4] with the length of 150mm and
thickness of 0.5mm can be inserted as shown in the picture below.
Содержание imageRUNNER ADVANCE C5000 Series
Страница 1: ...im C mageRU Canon U UNNER U S A In T ADVAN nc ech W NCE C9 hni Wo 9000 Ser cal Work ries l kboo ok ...
Страница 3: ...1 Symptoms Solutions For the imageRUNNER ADVANCE C9075 C7065 Series ...
Страница 49: ...47 b 23 Remove the 2 screws 1 1 stepped screw 2 and 1 hook 3 to detach the hopper unit Bk 4 ...