e-Support Filename:
TP10 123b.pdf
Date:
06-19-13
Page 12 of 15
For the sensors [B] [C], disconnect the connector and remove the sensors.
Step3
: Clean the light-emitting surface [3] and the light-receiving surface [4] of the sensors
[A] [B] [C] with an air brush [5]. ( See photos below )
If necessary, clean the sensors with a cloth or a lint free paper towel damp with alcohol.
Note: When cleaning it with cloth or paper towel, pay close attention so that toner or dirt
does not get into the slit opening [6] at the light-emitting surface [3] and the light-receiving
surface [4]. If foreign material becomes lodged into the slits the sensor may malfunction.
Y/M/C Hopper
When detaching the Yellow Hopper, remove the screws [Y-1] [Y-2] as seen on top photo on the
next page and then detach the Hopper.
After detaching the Hopper of the affected color, remove the sensors [D] [E] [F] in the same manner
as the Bk sensor and clean it in the same fashion. (See pictures in the following page).
B
C
[A/B/C]
[5]
[3]
[4]
[6]
Color Hoppers must be detached in the following order: Yellow, Magenta, and Cyan.