PRODUCTS AFFECTED / SERIAL NUMBERS AFFECTED:
imageRUNNER ADVANCE C9075PRO / C9065 PRO / C7065 / C7055 / C9075S PRO / C9065S PRO /
C9280 PRO / C9270 PRO / C7270 / C7260 Series
SUBJECT:
Minimizing E025 Error Codes
GENERAL:
This Technical Publication details how to minimize E025 error codes.
DETAILS:
Typically, an E025 error code occurs when a phenomenon with a hopper assembly occurs. Below is a list
of a few of those situations:
Error
Code
Details
E025
‐
0100
/
0200
/
0300
/
0400
Toner
Container
drive
motor
lock
error
(0100:Y,
0200:M,
0300:C,
0400:Bk)
E025
‐
0x02
Block
supply
timeout
error.
The
toner
supply
screw
rotation
sensor
cannot
detect
rotation
of
the
screw
(x
=
1:
Y,
2:
M,
3:
C,
4:
Bk)
E025
‐
0x20
Toner
cap
position
sensor
time
out
error
(x
=
1:
Y,
2:
M,
3:
C,
4:
Bk)
E025
‐
0xA0
/
0xB0
Unable
to
detect
the
Release
Holder
Shift
Cam
HP
Sensor
status
when
opening
the
toner
cap,
so
that
open
and
close
status
of
the
toner
cap
is
unable
to
be
judged.
(x
=
1:
Y,
2:
M,
3:
C,
4:
Bk)
Unable
to
detect
the
Release
Holder
Shift
Cam
HP
Sensor
status
when
closing
the
toner
cap,
so
that
open
and
close
status
of
the
toner
cap
is
unable
to
be
judged.
(x
=
1:
Y,
2:
M,
3:
C,
4:
Bk)
E025
‐
0xC0
Error
in
Toner
Insertion
Inlet
Cover
Sensor
(x
=
1:
Y,
2:
M,
3:
C,
4:
Bk)
On the next page are more detailed explanations and causes for the aforementioned E025 sub codes.
THIS TECHNICAL PUBLICATION IS THE PROPERTY OF CANON U.S.A. INC. AND CONTAINS CONFIDENTIAL INFORMATION OWNED BY OR LICENSED TO,
CANON U.S.A., AUTHORIZED CANON U.S.A., DEALERS MAY USE THIS TECHNICAL PUBLICATION FOR REFERENCE PURPOSES ONLY. ANY OTHER USE
BY AN AUTHORIZED CANON USA DEALER, OR USE BY ANY THIRD PARTY, IS PROHIBITED.
For additional technical information, please visit the Canon Engineering Services and Solutions Division website at:
www.support.cusa.canon.com. You can also call the Technical Support Center at 1-800-528-2830 or contact your Regional Support Office.
Содержание imageRUNNER ADVANCE C5000 Series
Страница 1: ...im C mageRU Canon U UNNER U S A In T ADVAN nc ech W NCE C9 hni Wo 9000 Ser cal Work ries l kboo ok ...
Страница 3: ...1 Symptoms Solutions For the imageRUNNER ADVANCE C9075 C7065 Series ...
Страница 49: ...47 b 23 Remove the 2 screws 1 1 stepped screw 2 and 1 hook 3 to detach the hopper unit Bk 4 ...