014-0003-05
Fixing Motor error
Detection Description
There was no FG signal input for 0.3 sec from the startup of the Fixing Motor.
Remedy
[Related parts]
- Harnesses from the DC Controller PCB to the Fixing Motor
1. DC Controller PCB (UN04/J122) to Relay Connector (8P) (Unit of replacement: CABLE, FEED)
2. Relay Connector (8P) to Fixing Motor (M09/J1019) (Unit of replacement: FIXING DRIVE
ASSEMBLY)
- Fixing Unit (Unit of replacement: FIXING ASSEMBLY)
- Gears in the Fixing Unit
1. Cam Gear (Unit of replacement: CAM/GEAR, 3T/21T)
2. Pressure Roller Gear (Unit of replacement: GEAR, 36T)
- Fixing Motor (M09) (Unit of replacement: FIXING DRIVE MOTOR ASSEMBLY)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
- Low Voltage Power Supply PCB (UN01) (Unit of replacement: POWER SUPPLY ASSEMBLY)
[Remedy] Perform the following in the order while checking whether the error is cleared.
1. Check that the Fixing Unit is pushed into the host machine so the handle is locked.
2. Remove the Fixing Unit, and rotate the Cam Gear and the Pressure Roller Gear by hand to
visually check that there is no bent or missing teeth or abnormal abrasion (edge of the gear is no
longer tooth-shaped).
3. Replace the Fixing Unit.
4. Check the harness between the DC Controller PCB and the Fixing Motor.
5. Measure the both ends of the fuse in the Low Voltage Power Supply PCB using a tester.
a. If the measurement value is less than 1 ohm (conduction state),
1. Replace the Fixing Motor.
2. Replace the DC Controller PCB.
b. If the measurement value is 1 ohm or higher (non conduction state), replace the Low Voltage
Power Supply PCB.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
020-01A8-05
Toner Density Sensor (Y) output error
Detection Description
The output value of the Toner Density Sensor (Y) in the Developing Unit (Y) did not fall within the
range between 38 and 214 for 2 consecutive times during printing.
Remedy
[Related parts]
- Harnesses from the Toner Density Sensor (Y) to the DC Controller PCB
1. Toner Density Sensor (Y) (UN21/J1050) to Developing Unit (Y) (J1040) (Unit of replacement:
CABLE, DEVELOPING)
2. Developing Unit (Y) (J1040) to Relay Connector (4P) (Unit of replacement: CABLE, RELAY)
3. Relay Connector (4P) to DC Controller PCB (UN04/J128) (Unit of replacement: CABLE,
SENSOR)
- Developing Unit (Y) (Unit of replacement: DEVELOPING ASSEMBLY, Y)
- DC Controller PCB (UN04) (Unit of replacement: DC CONTROLLER PCB ASSEMBLY)
[Remedy] Check/replace the related harness/cable, connector and parts.
[Reference] Before replacing the DC Controller PCB, back up the service mode data (approx. 2
min) and restore the backup data after the replacement so the data may be able to be protected.
- Backup: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMBUP
- Restoration: COPIER (LEVEL2)> FUNCTION> SYSTEM> DSRAMRES
7. Error/Jam/Alarm
525
Содержание imageRUNNER ADVANCE C3320 Series
Страница 1: ...Revision 7 0 imageRUNNER ADVANCE C3330 C3325 C3320 Series Service Manual ...
Страница 18: ...Product Overview 1 Product Lineup 7 Features 11 Specifications 17 Parts Name 26 ...
Страница 278: ...J1335 J1066 J1022 J1146 J1050 J1051 J130 J1052 J1053 J1333 J120 J128 J130 4 Parts Replacement and Cleaning 266 ...
Страница 326: ...CAUTION Check that the color of the seal at the center is black 4 Parts Replacement and Cleaning 314 ...
Страница 359: ...6 Remove the Bottle Drive Unit 1 2 Bosses 2 5 Hooks 3 2 2 3 3 3 2 2 1 3 3 3 3 4 Parts Replacement and Cleaning 347 ...
Страница 399: ...Adjustment 5 Pickup Feed System 388 Document Exposure System 391 Actions after Replacement 393 ...
Страница 518: ...Error Jam Alarm 7 Overview 507 Error Code 511 Jam Code 617 Alarm Code 624 ...
Страница 1020: ...9 Installation 1008 ...
Страница 1022: ...2 Perform steps 3 to 5 in each cassette 9 Installation 1010 ...
Страница 1024: ...5 6 Checking the Contents Cassette Feeding Unit 1x 3x 2x 1x 9 Installation 1012 ...
Страница 1027: ...3 4 NOTE The removed cover will be used in step 6 5 2x 2x 9 Installation 1015 ...
Страница 1046: ...When the Kit Is Not Used 1 2 Close the Cassette 2 When the Kit Is Used 1 9 Installation 1034 ...
Страница 1058: ...3 4 CAUTION Be sure that the Inner 2 way Tray Support Member is installed properly 9 Installation 1046 ...
Страница 1062: ...Installation procedure 1 NOTE The work is the same when the Utility Tray is installed 9 Installation 1050 ...
Страница 1068: ... Removing the Covers 1 2x 2 1x 9 Installation 1056 ...
Страница 1070: ...3 1x 1x 9 Installation 1058 ...
Страница 1080: ...Installation Outline Drawing Installation Procedure 1 Remove the all tapes from this equipment 2 2x 9 Installation 1068 ...
Страница 1081: ...3 CAUTION To avoid damage do not pull the A part of the Utility Tray too much A 4 9 Installation 1069 ...
Страница 1083: ...6 7 TP M4x8 2x 2x 9 Installation 1071 ...
Страница 1084: ...When Installing the USB Keyboard 1 Cap Cover Wire Saddle 9 Installation 1072 ...
Страница 1095: ...9 2x 10 2x 11 Remove the Face Seals from the Reader Right Cover The removed Face Seals will not be used 9 Installation 1083 ...
Страница 1101: ... When Stopping to Use 1 Press Reset key or the Voice Recognition button for more than 3 seconds 9 Installation 1089 ...
Страница 1129: ...9 2x 10 2x 11 9 Installation 1117 ...
Страница 1135: ...Remove the covers 1 ws 2x 2 1x 9 Installation 1123 ...
Страница 1140: ...2 2x 3 Connect the power plug to the outlet 4 Turn ON the power switch 9 Installation 1128 ...
Страница 1155: ...Installation Outline Drawing Installation Procedure Removing the Covers 1 2x 2 1x 9 Installation 1143 ...
Страница 1157: ...3 Connect Power Cable and Signal Cable disconnected in the step 2 to the Encryption Board 2 Connectors 2x 9 Installation 1145 ...
Страница 1167: ...Installation Procedure Removing the Covers 1 2x 2 1x 3 2x Installing the Removable HDD Kit 9 Installation 1155 ...
Страница 1176: ... A 2x Installing the Covers 1 1x 2 2x 9 Installation 1164 ...
Страница 1177: ...3 4 2x Installing the Removable HDD 1 Install the HDD Unit to the HDD Slot 9 Installation 1165 ...
Страница 1182: ...Installation Outline Drawing Installation Procedure Removing the Covers 1 2x 2 1x 9 Installation 1170 ...
Страница 1190: ...14 Install the Cable Guide to the HDD Frame 4 Hooks 1 Boss 9 Installation 1178 ...
Страница 1195: ...23 Secure the Power Cable in place using the Wire Saddle 1x Installing the Covers 1 1x 2 2x 9 Installation 1183 ...
Страница 1196: ...3 4 2x Installing the Removable HDD 1 Install the HDD Unit to the HDD Slot 9 Installation 1184 ...