pg. 66
Symptom
0111/0C10/0112/0113/0114 jam code emerges owing to the defective Upper Separation Claw ot
the Fixing Assembly
[Inspected by Canon Inc.]
Description
- 0C10 jam occurred in Field cases.
- 0111: Fixing Outlet Sensor Delay Jam
- 0C10: Fixing Claw jam
- 0112: Inner Delivery Sensor Delay Jam
- 0113: Outer Delivery Sensor Delay Jam
- 0114: Reverse Vertical Path Sensor Delay Jam
Cause
Owing to the aging of the upper separation claw[1] of the fixing assembly, the jam occurred because of the
deformation or the chipped tip of the claw.
Field Remedy
When the upper separation claw is dirty, clean it with the lint-free paper wetted with alcohol. If the claw is
deformed or the tip of the claw is chipped, then replace it with the new upper separation claw (FB5-3625).
[Reference] Upper separation claw is a consumable part to be replaced at every 500,000 prints.
[Replacement Part]
FB5-3625 CLAW, SEPARATING