Symptom
Image soil/smear due to the failure in installing the blade retainer
[Inspected by Canon Inc. ]
Description
Image soil or image smear appeared on a machine with a serial number earlier than the serial number
below:
Models
Serial #
Models
Serial #
iR-ADV 8105 V2 120V
HMU11159
iR-ADV 8105 V2 230V EUR
HMW01074
iR-ADVDV 8105G V2 120V
HMV10032
iR-ADV 8095 V2 230V EUR
HNC01073
iR-ADV 8095 V2 120V
HNA11788
iR-ADV 8085 V2 230V EUR
HNK01261
iR-ADV 8095G V2 120V
HNB10058
iR-ADV 8105 V2 230V
HMX00688
iR-ADV 8085 V2 120V
HNG10677
iR-ADV 8095 V2 230V
HND00645
iR-ADV 8085G V2 120V
HNH10073
iR-ADV 8085 V2 230V
HNL00542
iR-ADV 8105 V2 220V CN
HMY00521
iR-ADV 8095 V2 220V CN
HNE00527
Cause
Due to the backlash in the screw-tightening of the blade retainer [1] for the cleaning blade, contact failure
occurred between the cleaning blade and the drum, causing the symptom.
Field Remedy
Prepare the new type blade retainer (FL3-5194-020) in which the screw holes for installing the cleaning
blade have been changed. Replace the parts following the steps below.
[Reference] Change the old type [A] to the new type [B] as follows, so as to fix the position for installing the
blade retainer.
- For [a], change the diameter of the circular hole for the installing screw from 3mm to 4mm.
- For [b], change the diameter of the circular hole in the blade retainer from 5mm to 3mm.
- For [c], disuse the circular holes, in the new type blade retainer.
- For [d], change the shape of the circular hole in the blade retainer to the long hole.
- For [e], change the long hole for the installing screw to the circular hole.