iPF6400S Basic Guide
60
C
ons
uma
bles
a
nd
M
ain
te
na
nc
e
C
le
an
in
g t
he
P
rint
er
3
If the Up-down Unit is lowered, open the
Spectrophotometer Unit Cover and lift up the
central part (near the blue label) of the Up-down
Unit.
Important
• Lifting up the ends of the Up-down Unit may cause damage.
4
Wipe the surface of the Spectrophotometer Eject
Guide and the surface of the White/Black
Backing Plate clean with a dry, soft cloth.
If it is particularly dirty, use a damp cloth that you
have wrung out completely to wipe clean and
use a dry cloth to dry the surface.
Warning
• Never use flammable solvents such as alcohol, benzene, or thinner. If these
substances come into contact with electrical components inside the printer, there is a
risk of fire or electrical shock.
Important
• When handling the White/Black Backing
Plate, do not touch the white backing
plate (a) or black backing plate (b) directly
with your hands.
If the surface becomes dirty or scratched,
the printer may not be able to obtain the
correct color measurement results.
• Make sure that no dirt remains in the
grooves on both ends of the
Spectrophotometer Eject Guide.
If any dirt remains, the printer may not be
able to obtain the correct color
measurement results.
Cleaning the Paper presser
Dirt on the surface of the Paper presser may be transferred onto the paper or the White/Black
Backing Plate.
1
Turn the printer off.
(See "Turning the Printer On and Off.")
➔
User's Guide
2
Unplug the power cord from the outlet.
Caution
• Always turn off the printer and unplug the power cord before cleaning or maintenance.
Accidentally leaving the printer on poses a risk of injury if you touch moving parts inside
the printer.