E750-2012 at installation
-> New item
Description
E750-2012 has occurred at installation.
Cause
Mistake in connecting the relay drawer connectors [1] and [2] at the lower side of the back
of the sub station.
Remedy
If the above symptom occurs, check whether the relay drawer connector has been correctly
connected at the lower side of the sub station. If it is incorrectly connected, connect it correctly.
[1]
Drawer connector (upper) purple
[2]
Drawer connector (lower) yellow
[A]
Correct
[B]
Incorrect
Содержание imagePRESS C7000VP Series
Страница 17: ...Trouble Shooting Information for C7000VP series Page 17 Rev 2 0 2010 09 17 ...
Страница 32: ...Trouble Shooting Information for C7000VP series Page 32 Rev 2 0 2010 09 17 ...
Страница 33: ...Trouble Shooting Information for C7000VP series Page 33 Rev 2 0 2010 09 17 ...
Страница 34: ...Trouble Shooting Information for C7000VP series Page 34 Rev 2 0 2010 09 17 ...
Страница 35: ...Trouble Shooting Information for C7000VP series Page 35 Rev 2 0 2010 09 17 ...
Страница 36: ...Trouble Shooting Information for C7000VP series Page 36 Rev 2 0 2010 09 17 ...
Страница 37: ...Trouble Shooting Information for C7000VP series Page 37 Rev 2 0 2010 09 17 ...
Страница 38: ...Trouble Shooting Information for C7000VP series Page 38 Rev 2 0 2010 09 17 ...
Страница 39: ...Trouble Shooting Information for C7000VP series Page 39 Rev 2 0 2010 09 17 ...
Страница 40: ...Trouble Shooting Information for C7000VP series Page 40 Rev 2 0 2010 09 17 ...
Страница 41: ...Trouble Shooting Information for C7000VP series Page 41 Rev 2 0 2010 09 17 ...
Страница 132: ...Trouble Shooting Information for C7000VP series Page 132 Rev 2 0 2010 09 17 Appendix 2 Fan installation ...
Страница 133: ...Trouble Shooting Information for C7000VP series Page 133 Rev 2 0 2010 09 17 ...
Страница 134: ...Trouble Shooting Information for C7000VP series Page 134 Rev 2 0 2010 09 17 ...