b. Change
These values are changed when the
control PCB is replaced. After the replacing
the control PCB, input the same values as
before the replacement. If you don't know
the values before the replacement, input the
estimated values.
After changing the value, select the [Set]
button at the right side of each item to fi-
nalize it. Pressing the [Set] button in the
lower right portion of the screen finalizes
values for all items.
However, [Roller Count] and [Pad
Count] has a [Reset] button instead of the
[Set] button. If this [Reset] button is selected,
the value becomes “0 (zero)”. Since it is
interlocked with the “Count Reset” for the
user, do not select the [Reset] button by
mistake.
If you replace the control PCB or change
the [Total Count], the [Roller Count] and
[Pad Count] are also changed. As the “Re-
placement message” may be displayed the
next time the user turns the power ON or the
count be incorrect, reset the count if nec-