background image

HARDWARE MANUAL

9222-2887-11 P-A208

E

Summary of Contents for DIMAGE SCAN MULTI PRO

Page 1: ...HARDWARE MANUAL 9222 2887 11 P A208 E ...

Page 2: ...leased after this date contact a Minolta Service Facility www minoltasupport com This product is designed to work with accessories manufac tured and distributed by Minolta Using accessories or equipment not endorsed by Minolta may result in unsatisfactory performance or damage to the product and its accessories Check the packing list before using this product If any items are missing immediately c...

Page 3: ... gasoline benzine or paint thinner Do not use inflammable products such as alcohol benzine or paint thinner to clean the product The use of inflammable cleaners and solvents may cause an explosion or fire When unplugging the unit do not pull on the power cord Hold the plug when removing the cord from an outlet Do not damage twist modify heat or place heavy objects on the power cord A damaged cord ...

Page 4: ...anner notes 16 Easy Scan Utility 16 About the DiMAGE Scan Utility 16 Film format and type settings 16 Disconnecting the scanner 16 SCSI cable 16 IEEE 1394 FireWire cable 16 Digital ICE3 system requirements 18 Scanner resolution 19 Scanner color profiles 19 Job file lists 20 35mm 20 6 X 4 5 21 6 X 6 22 6 X 7 23 6 X 8 24 6 X 9 and Multi format 6 X 9 25 Multi format 35mm 25 Troubleshooting 26 Checkin...

Page 5: ...nstalled Windows Me 2000 Professional XP Mac OS 8 6 to 9 2 2 and OS 10 1 3 to 10 1 5 A 640 x 480 pixel monitor capable of displaying 32 000 colors is required 1024 x 768 pixels is recommended SCSI PowerPC 604 or later FireWire PowerPC G3 or later PowerPC G4 processor is recommended when scanning with 16 bit color depth For Digital ICE3 requirements see page18 Plug in compatible with Photoshop 5 0 ...

Page 6: ...lide Mount Holder p 10 35mm Film Holder p 10 Universal Holder p 11 Film attachments Film masks Front door Indicator lamp Power switch Eject button SCSI ID switch IEEE 1394 FireWire ports Dip switch AC terminal SCSI ports ...

Page 7: ...f the computer and scanner Disconnect the cable and power cord from the scanner and screw the optic locking screw in the lock position Removing the optics locking screw Before the scanner can be used the optics locking screw on the bottom panel of the scanner must be removed with a flat head screwdriver The locking screw is necessary to transport the scanner Place the screw in the storage position...

Page 8: ...re within a daisy chain switch 1 should be in the off position The initial setting for all the switches is on Dip switch 4 must be in the on position to use a SCSI interface Connect the scanner to the computer or SCSI chain with the cable Either SCSI port can be used for the connection Plug the power cord into the back of the unit The other end of the power cord should be plugged into a grounded o...

Page 9: ... Switch 4 must be moved to the on position if a SCSI cable is used Connect the scanner to the computer or IEEE peripheral chain with the cable Either IEEE port can be used for the connection Plug the power cord into the back of the unit The other end of the power cord should be plugged into a grounded outlet Auto Power Save The scanner automatically turns the scan ning light source off during long...

Page 10: ...e or dirt from film carefully follow the manufacturer s instructions and precautions for the film cleaning solvent Loading 35mm film strips The 35mm Film Holder FH P1 is for unmounted 35mm film Film strips up to six frames in length can be placed in the holder With the cover hinges away from you open the holder by lifting on the latch on the cover With the emulsion down place the film sideways int...

Page 11: ...and auto exposure functions see the DiMAGE Scan Utility manual Inserting attachments into the Universal Holder The Universal Holder is used for scanning medium format film All standard formats from 6X4 5 to 6X9 can be scanned Two attachments with and without glass are supplied with the holder An attachment must be inserted to hold the film With the hinge to the top slide the left side of the attac...

Page 12: ...attach ment and lift the cover Slide the tabs of the appropriate mask into the corresponding slots on each side of the attachment hinge Fit the holes on the other side of the mask 1 over the registration pins 2 on the base of the attachment Always use a mask when scanning or newton rings and flare may degrade the image quality With the emulsion down place the film on the mask Align the frame with ...

Page 13: ...aligned to the two slots in the holder Carefully press the right side of the base down until the latch in the Universal Holder clicks Insert the two pin on the attachment cover into the two corresponding holes in the Universal Holder Both pins should click into place The Multi format attachment is designed for non standard film sizes special technical films and non photographic transparent media T...

Page 14: ...e holes on the other side of the mask 2 over the registration pins on the base of the the holder on each side of the cover hinges With the emulsion down place the film on the mask Align the image area with the mask aper ture Carefully close the cover until the latch clicks See page 15 for instructions on how to load the holder into the scanner 1 To remove the film slide the latch toward the center...

Page 15: ...p blinks during this period Loading a film holder into the scanner Before using the scanner install the DiMAGE Scan Utility see the software instruction manual Turn on the scanner and then start the computer Launch the DiMAGE Scan Utility before insert ing the film holder Insert the film holder into the scanner in the direction indicated by the white arrow Hold the holder straight and level when i...

Page 16: ...lti format attachment when scanning specialized film or non photographic originals such as microfilm or microscope slides Also for the Multi format attachment the TEM film option is for transmission electron microscopy film Disconnecting the scanner SCSI cable The scanner and computer must be turned off before the SCSI cable can be disconnected If the scanner is connected to a SCSI chain all the d...

Page 17: ... disconnect the cable When more than one external device are connected to the computer repeat the procedure above except right click on the unplug or eject hardware icon This will open the unplug or eject hardware window after clicking on the small window indicating the unplug operation On the unplug or eject hardware window the hardware devices to be stopped will be displayed Highlight the device...

Page 18: ... 1 2GB 2GB 4GB 2GB 3GB 6GB Recommended system requirements 35 mm Multi format 35 mm 6 X 9 SCSI or IEEE 1394 8 bit Pentium III or later 2GB 35 mm Multi format 35 mm 6 X 9 16 bit 512MB 4GB 6GB 3GB 4GB 8GB Macintosh computers When determining the RAM available for a Macintosh computer the volume required for the oper ating system and any application in use must be subtracted from the total memory all...

Page 19: ...th positive film with 16 bit linear color depth The profiles are located in the following locations Scanner resolution The maximum resolution of this scanner is 4800 X 4800 dpi The maximum optical resolution varies with the format of the film 35 mm film 4800 X 4800 medium format film 3200 X 4800 Scans of medium format film can have a final resolution of 4800 X 4800 dpi through interpolation The mi...

Page 20: ...oto4x6 1214 300 404 mm 37 13 24 75 OFF 150 100 ON 1771 1181 Photo3x5 1068 300 356 mm 35 67 25 OFF 127 89 ON 1500 1051 WebPage 1240x836 850 72 1180 pixel 1240 836 OFF 1240 836 ON 1240 836 1112x750 762 72 1058 pixel 1112 750 OFF 1112 750 ON 1112 750 984x663 674 72 936 pixel 984 663 OFF 984 663 ON 984 663 792x534 543 72 754 pixel 792 534 OFF 792 534 ON 792 534 760x512 521 72 723 pixel 760 512 OFF 760...

Page 21: ... 300 506 inch 1 68 2 15 OFF 8 5 10 9 ON 2550 3270 LetterHalf 1145 300 381 inch 1 43 2 23 OFF 5 45 8 5 ON 1635 2550 LetterQuarter 759 300 253 inch 1 68 2 15 OFF 4 25 5 45 ON 1275 1635 Photo4x6 796 300 265 mm 37 74 56 6 OFF 100 150 ON 1181 1771 Photo3x5 674 300 224 mm 39 73 56 7 OFF 89 127 ON 1051 1500 WebPage 1240x935 557 72 773 pixel 935 1240 OFF 935 1240 ON 935 1240 1112x839 500 72 694 pixel 839 ...

Page 22: ...05 105 ON 1240 1240 LetterFull 1145 300 381 inch 2 23 2 23 OFF 8 5 8 5 ON 2550 2550 LetterHalf 735 300 245 inch 2 22 2 22 OFF 5 45 5 45 ON 1635 1635 LetterQuarter 573 300 191 inch 2 23 2 23 OFF 4 25 4 25 ON 1275 1275 Photo4x6 531 300 177 mm 56 5 56 5 OFF 100 100 ON 1181 1181 Photo3x5 472 300 157 mm 56 69 56 69 OFF 89 89 ON 1051 1051 WebPage 1240x1240 557 72 773 pixel 1240 1240 OFF 1240 1240 ON 124...

Page 23: ...05 ON 1748 1240 LetterFull 1185 300 395 inch 2 76 2 15 OFF 10 9 8 5 ON 3270 2550 LetterHalf 924 300 308 inch 2 76 1 77 OFF 8 5 5 45 ON 2550 1635 LetterQuarter 593 300 197 inch 2 77 2 16 OFF 5 45 4 25 ON 1635 1275 Photo4x6 642 300 214 mm 70 09 46 73 OFF 150 100 ON 1771 1181 Photo3x5 544 300 181 mm 70 17 49 17 OFF 127 89 ON 1500 1051 WebPage 1240x1000 450 72 625 pixel 1240 1000 OFF 1240 1000 ON 1240...

Page 24: ... 69 OFF 148 105 ON 1748 1240 LetterFull 1145 300 381 inch 2 86 2 23 OFF 10 9 8 5 ON 3270 2550 LetterHalf 840 300 280 inch 3 04 1 95 OFF 8 5 5 45 ON 2550 1635 LetterQuarter 573 300 191 inch 2 85 2 23 OFF 5 45 4 25 ON 1635 1275 Photo4x6 584 300 194 mm 77 32 51 55 OFF 150 100 ON 1771 1181 Photo3x5 494 300 164 mm 77 44 54 27 OFF 127 89 ON 1500 1051 WebPage 1240x909 409 72 568 pixel 1240 909 OFF 1240 9...

Page 25: ...00 261 mm 80 46 56 71 OFF 210 148 ON 2480 1748 A4Quarter 557 300 185 mm 80 56 76 OFF 148 105 ON 1748 1240 LetterFull 1145 300 381 inch 2 86 2 23 OFF 10 9 8 5 ON 3270 2550 LetterHalf 773 300 257 inch 3 31 2 12 OFF 8 5 5 45 ON 2550 1635 LetterQuarter 573 300 191 inch 2 85 2 23 OFF 5 45 4 25 ON 1635 1275 Photo4x6 537 300 179 mm 83 8 55 87 OFF 150 100 ON 1771 1181 Photo3x5 472 300 157 mm 80 89 56 69 O...

Page 26: ...fore inserting the film holder Indicator lamp is red Confirm the optic locking screw is removed from the lock position on the bottom panel of the scanner p 7 If the screw is removed and the lamp is still red con tact a Minolta service facility The set film message appears Confirm film has been loaded into the holder The set film holder message appears The holder in the scanner and the film type se...

Page 27: ...on of the device manager Click on the location to display the files When using a SCSI interface with Windows 98 or Me Minolta 2887 should be listed as the imaging device For Windows 2000 Professional and XP Minolta DiMAGE Scan Multi PRO should be listed as the imaging device When using an IEEE interface Minolta DiMAGE Scan Multi PRO should be listed as the imaging device If these files are not loc...

Page 28: ...e main window 5 A description of the problem 6 Any message that appears on the screen when the problem occurs 7 The frequency of occurrence Warranty and product registration Please take the time to fill in the warranty and product registration card Technical support scan ner software upgrades and product information are available when the product is registered Image data sheet On the following pag...

Page 29: ...n Magenta Yellow Black Amount Radius Threshold Shadow Image correction Job Digital ICE Digital ROC Digital GEM Exposure control Exposure control setting file Master Red Green Blue Scan settings Job name Input resolution Input size W Input size H Magnification Output resolution Output size W Output size H Unit Color space ICC profile Color matching Auto exposure Color depth Multi sample scan Prefer...

Page 30: ...40V AC 50 60 Hz Power consumption 40W maximum Dimensions 168 W X 128 H X 377 D mm 6 6 W X 5 0 H X 14 8 D in Weight Approximately 4kg 8 8lb Operating environment 10 35 C 50 95 F 15 80 humidity Film Scan type Time IBM PC AT Time Macintosh 35mm color positive 6 X 9 color positive Prescan Scan Prescan Scan 9 seconds 49 seconds 13 seconds 3 minutes 10 seconds 56 seconds 16 seconds 3 minutes 50 seconds ...

Page 31: ...ergy efficiency Microsoft Windows Windows 98 Windows Me Windows 2000 Professional and Windows NT are regis tered trademarks of the Microsoft Corporation Macintosh Apple and Power Macintosh are registered trade marks of Apple Computer Inc Adobe and Photoshop are registered trademarks of Adobe Systems Incorporated Digital ICE3 Digital ICE Digital ROC and Digital GEM are trademarks of registered trad...

Page 32: ...9222 2887 11 P A208 Printed in Germany 2002 Minolta Co Ltd under the Berne Convention and the Universal Copyright Convention 0 43325 53110 1 ...

Reviews: