CHAPTER 4 INSTALLATION & MAINTENANCE
b. Auto Start switch "OFF"
1) Click the [Start] button on the computer,
and click [All Programs], [Canon P-215],
[Utilities].
2) The Canon imageFORMULA utility starts
and a screen is displayed.
Figure 4-306
3) Select [Canon P-215 USB], and click
[Properties]. When the screen is displayed,
click the [Maintenance] tab.
Figure 4-307
4) Click the corresponding "Reset" button.
3. Service Maintenance
For this machine, no periodical mainte-
nance item by the service technicians is
specified.
However, when visiting a user, check
whether the reading glasses and the rollers
are dirty. If they are very dirty, instruct the user
to follow the “User Maintenance” procedures.
Recommend the user to replace consumable
parts if necessary.