6
6
6-9
6-9
Installation > Installation Procedure > Connecting this Machine
Installation > Installation Procedure > Connecting this Machine
6) Remove the Reader Support Plate A. (removed Reader Support Plate A will be used in step
7.)
• 2 Screws (removed screw will be used in step 7.)
x2
Reader Support Plate A
Reader Support
Plate A
7) Remove the tags from the Reader Support Plate A, B, and attach them with the 2 screws
removed in step 6 as shown in the figure.
x2
Reader Support Plate A
Reader Support Plate B
F-6-20
F-6-21
8) Put the Reader Support Plate of step 7 under the Cable and install.
• 1 screw (screws removed in step 4.)
NOTE:
When replacing the Laser Unit, it is necessary to remove the Reader Unit from the main
unit. And the Support Plate needs to be installed to the Reader Unit for the removal.
9) Remove the 2 Scanner System Fixation Screws. (The removed Scanner System Fixation
Screws will not be used.)
x2
F-6-22