OSD Menu
67
Sub Menu
Setting Options (Bold: factory default)
Time Code
3
Display the time code superimposed on the signal.
VITC 01:23:45.05
Enable
On,
Off
Switches the time code display On, Off.
Type
4
VITC
LTC
Selects the type.
Size
Large
Small
Selects the size.
Position
5
Top Left
Top Right
Bottom Left
Bottom Right
Selects the display position.
Wave Form Monitor
6
Configures various settings for the wave form monitor. On the wave form monitor, the horizontal axis
shows the horizontal resolution of the video and the vertical line shows the signal level. To the right of
the wave form monitor, [Color Range] and [HDR Range] information (vertical line) is displayed.
255
-4%
0%
50 %
100 %
0
Signal level
IRE
Horizontal resolution of video
Enable
On,
Off
Switches the wave form monitor On, Off.
Select Signal
Y
, Cb, Cr, R, G, B
Sets the waveform to be displayed.
Display Type
All
Line
Sets the display type.
[Line]: The data for one line is displayed.
Select Line
1
to 2160
Selects the line to be displayed when [Line] is selected.
Position
5
Bottom Left
Bottom Right
Selects the display position.
Scale
Automatic
IRE
Canon Log
Canon Log 2
Canon Log 3
ST 2084 (PQ) Full
ST 2084 (PQ) Limited
Hybrid Log-Gamma
Sets the scale of the wave form monitor.
[Automatic]: Sets in accordance with the [Gamma] and [Color Range]
settings.
Reference Line
4 to
1023
A guide is displayed at the specified position. [Reference Line] is not
displayed when [1023] is selected.