background image

4

Please read this manual before installing and using the heater.

1. Turn OFF the main gas supply.

2. Extinguish any open flame.

3. Open windows.

4. Do not touch electrical switches.

5. Do not use your telephone.

6. Call your gas supplier immediately from a neighbour’s phone.

1. Improper installation, adjustment, alteration, service or main-

tenance can cause injury or property damage.  Refer to other

sections of this manual for correct procedures, or consult with

place of purchase, a licensed plumber, a gas supplier or

service agent listed in this manual.

2. Due to high temperatures the room heater should be located

out of traffic and away from:

Furniture and draperies,

Combustible materials,

Gasoline and other flammable liquids,

Do not place clothing or other flammable material on or near

the heater.

3. Keep curtains*, clothing, furniture and other flammable mate-

rials at least 900mm from front, rear and sides of the heater.

* At the owner’s discretion curtain clearance can be less than

900mm as long as they are restrained from the front, top and

sides of the heater. The manufacturer takes no responsibility if

curtain clearance is less than 900mm and not restrained.

4. Children and adults should be alerted to the hazard of high

surface temperature and should take care to avoid burns or

clothing ignition.

Young children should be carefully supervised when they are

in the same room as the heater.

5. Never attempt to burn paper or any other material in the

heater.

6. Do not spray aerosols in the vicinity of this appliance while it

is in operation.

7.  If removed the glass window must be put back onto the unit

prior to operating the heater.

8. Installation and repairs should be performed by a licensed

service person only, refer to back of brochure for service

number.

Safety Warnings

What to do if you smell

gas

Warnings

21

9

No gas to burner.

• The gas valve should open at the same time as the

igniter sparks. If there is no gas to the burner when

this occurs check the solenoid coils for continuity.

• Check that the gas pressure is present at the test

point when the spark is being generated.

• Check that there is gas to the inlet of the gas control.

10

Appliance lights but goes

• Test the flame for correct ionisation signal. Connect a

into lockout.

multimeter in series with the flame rod and set the

function to measure micro-amps. The module will go

into lockout if the flame current sensitivity is less than

0.5 micro-amps. The approximate signal strength on

high flame is about 10 micro-amps and on low

4  micro-amps. The signal strength will fluctuate but

should be greater than 1.5 micro-amps at all times.

Take precaution because the ionisation probe can

have a high negative voltage and can cause shock.

11

Fuse blowing.

• If the fuse continues to blow check the solenoid coils

for signs of them being shorted.

• Check the fan is and wiring for short circuit.

Terminals 5, 6 and 7 at the module 12 way connector are bridged.

Terminal 10 at the module 12 way connector is the active supply

via the red wire.

Terminal 11 at the module 12 way connector is the neutral supply

via the blue wire.

Terminal 12 at the module 12 way connector is the earth connec-

tion via the green/yellow wire.

Terminal 12 at the module 2 way connector is the neutral connec-

tion via a brown wire which is joined into the rectifier cable then

into the 8 way switch connector blue wire.

Terminal 14 is an active connection at the module 2 way connec-

tor via a white wire into the 8 way switch connector. This is active

only when the flame is sensed.

Connections

28

Содержание FITZP

Страница 1: ...approved for use with Natural and Propane gases Please leave instructions with the owner FITZROY PROFILE MAKER S WARRANTY FREESTANDING MODELS FITZP FITZLP USER INSTRUCTIONS INSTALLATION INSTRUCTIONS...

Страница 2: ...ns 10 15 Clearances Installation Gas connection Fuel bed log installation Gas control Gas pressure point Flue installation 16 17 Flue kit Service instructions 18 19 General Access to components To rep...

Страница 3: ...its warranty voided If installation is not carried out in accordance with manufacturer s instructions this warranty may be void The customer must keep their Tax Invoice as proof of purchase of this p...

Страница 4: ...ns clothing furniture and other flammable mate rials at least 900mm from front rear and sides of the heater At the owner s discretion curtain clearance can be less than 900mm as long as they are restr...

Страница 5: ...ar after a few hours use at the maximum control position Important WHEN THIS HEATER IS OPERATING THE MESH GUARD IS HOT The mesh guard fitted to the heater conforms to AGA requirements For heaters fitt...

Страница 6: ...ure 2 3 To turn heater on press switch to POWER ON position There is a 5 second delay before the burner ignites At this setting the burner is on LOW and the fan speed is on LOW Refer figure 3 The burn...

Страница 7: ...tch for HIGH setting Refer figure 6 7 To turn the burner to LOW setting press switch for LOW set ting Refer figure 7 On low burner setting it is more efficient to operate the fan speed on LOW 8 If the...

Страница 8: ...attention contact your supplier or licensed service person listed in this manual Important The appliance should be inspected before use and at least annu ally by an authorised service person More fre...

Страница 9: ...20 kPa NG For Propane gas regulated to supply 2 65 kPa Gas regulator Integral with controller Fan Three speed Controller Electronic Power requirement 240 VAC 10 A Optional Accessories Safety guard Go...

Страница 10: ...efer to warning 3 on page 4 For minimum clearances refer fig 9 and 10 4 Remove the carton from the heater and lift from pallet Check that the heater is suitable for the gas available Please dispose of...

Страница 11: ...the heater front by pulling it towards you gently to partly disengage it from the body of the heater then gently lift it up vertically to completely disengage it Refer figure 13 11 Remove the inner g...

Страница 12: ...MUST BE HARD UP AGAINST REAR OF BURNER 14 Carefully unpack the log set Logs are numbered as follows No 1 Left front log No 2 left back log No 3 Right front log No 4 Right back log Position the four in...

Страница 13: ...in No 3 log Refer figure 20 15 Refit the inner glass but do not overtighten the screws 16 Refit the front glass surround Ensure that the glass surround is replaced the correct side up 17 Gas control l...

Страница 14: ...ll On position as indicated in figure 24 a and using a ring spanner as per figure 24 b adjust the pressure to 1kPa for Natural gas or 2 65 kPa for LPG Turn clockwise to increase pressure and anticlock...

Страница 15: ...ioned towards lower right hand side to clear the control 28 Refit the lower front cover making sure not to damage the power cord 29 Follow User Instructions to turn on heater Important To achieve the...

Страница 16: ...ocate against the wall 1 Ensure clearances to combustible have been observed For clear ances refer page 10 2 The centre line of the flue is 120mm to rear of appliance includ ing rear spacers 3 Carry o...

Страница 17: ...17 27...

Страница 18: ...eplace the fan 1 Disconnect the fan from the fan plug 2 Undo the two M5 wing nuts fixing the fan to the burner chamber underside 3 Replace in reverse order To replace the electronic controller 1 Remov...

Страница 19: ...pare parts contact the CANNON distributor in your state Sampford Staff Pty Ltd 421 Smith Street Fitzroy Vic 3065 Vic Tas 03 9418 5800 NSW 02 9331 8888 SA NT 08 8212 7000 Qld 07 3358 3000 WA 08 9242 53...

Страница 20: ...e wire into the 8 way switch connector will be energised as soon as the flame has been sensed 5 Confirm spark is produced A blue spark can be seen when the heater ignition when heater is turned on pro...

Страница 21: ...an 1 5 micro amps at all times Take precaution because the ionisation probe can have a high negative voltage and can cause shock 11 Fuse blowing If the fuse continues to blow check the solenoid coils...

Страница 22: ...22 Notes...

Страница 23: ...23 Notes...

Страница 24: ...F IN Part No F2774 Revision C Cannon FITZROY PROFILE...

Отзывы: