4
Please read this manual before installing and using the heater.
1. Turn OFF the main gas supply.
2. Extinguish any open flame.
3. Open windows.
4. Do not touch electrical switches.
5. Do not use your telephone.
6. Call your gas supplier immediately from a neighbour’s phone.
1. Improper installation, adjustment, alteration, service or main-
tenance can cause injury or property damage. Refer to other
sections of this manual for correct procedures, or consult with
place of purchase, a licensed plumber, a gas supplier or
service agent listed in this manual.
2. Due to high temperatures the room heater should be located
out of traffic and away from:
•
Furniture and draperies,
•
Combustible materials,
•
Gasoline and other flammable liquids,
Do not place clothing or other flammable material on or near
the heater.
3. Keep curtains*, clothing, furniture and other flammable mate-
rials at least 900mm from front, rear and sides of the heater.
* At the owner’s discretion curtain clearance can be less than
900mm as long as they are restrained from the front, top and
sides of the heater. The manufacturer takes no responsibility if
curtain clearance is less than 900mm and not restrained.
4. Children and adults should be alerted to the hazard of high
surface temperature and should take care to avoid burns or
clothing ignition.
Young children should be carefully supervised when they are
in the same room as the heater.
5. Never attempt to burn paper or any other material in the
heater.
6. Do not spray aerosols in the vicinity of this appliance while it
is in operation.
7. If removed the glass window must be put back onto the unit
prior to operating the heater.
8. Installation and repairs should be performed by a licensed
service person only, refer to back of brochure for service
number.
Safety Warnings
What to do if you smell
gas
Warnings
21
9
No gas to burner.
• The gas valve should open at the same time as the
igniter sparks. If there is no gas to the burner when
this occurs check the solenoid coils for continuity.
• Check that the gas pressure is present at the test
point when the spark is being generated.
• Check that there is gas to the inlet of the gas control.
10
Appliance lights but goes
• Test the flame for correct ionisation signal. Connect a
into lockout.
multimeter in series with the flame rod and set the
function to measure micro-amps. The module will go
into lockout if the flame current sensitivity is less than
0.5 micro-amps. The approximate signal strength on
high flame is about 10 micro-amps and on low
4 micro-amps. The signal strength will fluctuate but
should be greater than 1.5 micro-amps at all times.
Take precaution because the ionisation probe can
have a high negative voltage and can cause shock.
11
Fuse blowing.
• If the fuse continues to blow check the solenoid coils
for signs of them being shorted.
• Check the fan is and wiring for short circuit.
Terminals 5, 6 and 7 at the module 12 way connector are bridged.
Terminal 10 at the module 12 way connector is the active supply
via the red wire.
Terminal 11 at the module 12 way connector is the neutral supply
via the blue wire.
Terminal 12 at the module 12 way connector is the earth connec-
tion via the green/yellow wire.
Terminal 12 at the module 2 way connector is the neutral connec-
tion via a brown wire which is joined into the rectifier cable then
into the 8 way switch connector blue wire.
Terminal 14 is an active connection at the module 2 way connec-
tor via a white wire into the 8 way switch connector. This is active
only when the flame is sensed.