12
12. Connect incoming gas supply pipe at gas control inlet. The
inlet fitting is located 150mm in from the rear pedestal wall
RH side. Refer figure 15.
13. The fuel bed is contained within the burner chamber. Remove
the fuel bed transit packaging. Refer figure 16.
The fuel bed is retained by a spring clip fixed to the rear of the
burner chamber
FUEL BED MUST BE HARD UP AGAINST REAR OF BURNER
14. Carefully unpack the log set. Logs are numbered as follows:
No 1 - Left front log
No 2 - left back log
No 3 - Right front log
No 4 - Right back log
Position the four individually numbered logs in the following
order on the fuel bed as shown in figures 17-20. The male
locating pins in fuel bed must engage with corresponding
holes in the individual logs.
a) Place log No.1 onto the 2 front left pins on the fuel bed.
Refer figure 17.
Installation instructions continued
16
Gas connection
Fuel bed and log
installation
15
17
13
b) Place log No.2 onto the 2 left back pins. Refer figure 18.
c) Place log No.3 on single right front pin, ensure fork
locates over log No. 2. Refer figure 19.
d) Place log No. 4 on single right back pin, ensure left side
of log rests on depression in No. 3 log. Refer figure 20.
15. Refit the inner glass, but do not overtighten the screws.
16. Refit the front glass surround. Ensure that the glass surround is
replaced the correct side up.
17. Gas control layout is as indicated in figure 21.
Pressures for ‘Burner full on’ and ‘Burner low flame’ are
factory set, however if pressures need to be checked or
adjusted follow the procedures described below and on
the next two pages.
19
20
18
21
Gas control
Содержание FITZP
Страница 17: ...17 27...
Страница 22: ...22 Notes...
Страница 23: ...23 Notes...
Страница 24: ...F IN Part No F2774 Revision C Cannon FITZROY PROFILE...