SYSTEM 238 Installation Manual
Alpha Keypad Programming
Start Programming the Keypad
[Installer Combination] [*] [0] [1] [#]
Alpha Keypad Test
[*] [6] [7] [#]
Kill/Revive Panel
[Installer Combination] [*] [6] [9] [#]
Panel Programming
Start Programming the Panel
[Installer Combination] [*] [0] [#]
Function
Comments
Keystroke Sequence
The following Keypad Commands are Installer Only Commands:
Keypad Operation Command Summary
The majority of the keypad commands apply equally to the LED and Alpha II keypads. Some keypad commands, however, apply
to the LCD keypad only.
The following Keypad Commands apply to both the LED and Alpha II keypads:
Function
Comments
Keystroke Sequence
Arm/Disarm
Delays active
[Combination] [#]
Bypass Zone (n)
[n] is zone # 1 - 8; Combo may be required
[Combination] [Bypass] [n] [#]
Chime On/Off
Combo may be required
[Combination] [*] [5] [#]
Change Combo (via
Must be done by User #1
[Master Combo] [*] [0] [#]
Master Code)
[New Combo] [#] [New Combo] [#]
Clear Alarm Memory
[*] [1] [#]
Exit Programming
[*] [#]
Fire Alarm
Keypad activated
[F] (Hold for 3 seconds)
Group Bypass and Arm
Arms system and all zones programmed for
[Combination] [*] [4] [#]
group bypass, CL 30 - 3F, Digit Position (3),
are shunted simultaneously; Combo may be
required. (Also called Home Arming)
Group Bypass and Instant
Same as Group Bypass (above) except system
[Combination] [*] [4] [7] [#] or
Arm
is Instant Armed (Exit Delay operates normally,
[Combination] [*] [7] [4] [#]
upon expiration of Exit Delay, all delayed zones
are converted to Instant - No Entry Delay.
Combo may be required. (Also called
Instant/Home Arming)
Instant Arm
Arms system and delayed zones are converted
[Combination] [*] [7] [#]
to Instant (Exit Delay active, No Entry Delay);
Combo may be required
Keypad Activated RPS
If enabled, CL 0B(3); Combo may be required
[Combination] [*] [0] [2] [#]
Medical Alarm
Keypad activated
[E] (Hold for 3 seconds)
Police/Panic Alarm
Keypad activated
[P] (Hold for 3 seconds)
Reset Aux Power
If resettable devices are connected to
[*] [6] [2] [#]
Terminals 5 and 6 (also resets devices
connected to Loop 8 (e.g. 2-wire smoke
detectors)
Reset Panel
[Master Combination] [*] [6] [8] [#]
Test - Battery
Use after correcting Low Battery problem
[*] [6] [4] [#]
Test - Bells
Combo may be required
[Combination] [*] [6] [3] [#]
Test - Central Station
Combo may be required
[Combination] [*] [6] [1] [#]
Test - Local Walk Test
[*] [6] [0] [#]
NOTE: For additional information about Combination Command requirements, see page 24 and CL 09 (2).
Error Tones Toggle On/Off
[*] [5] [4] [#]
Audible Feedback Toggle
[*] [5] [1] [#]
Backlight Toggle On/Off
[*] [8] [#]
Display Keypad Model
[*] [9] [#]
& Revision Number
Chime Toggle
[*] [5] [3] [#]
Pre-warn Toggle On/Off
[*] [5] [2] [#]
Function
Comments
Keystroke Sequence
The following Keypad Commands apply to the Alpha II keypad only: