SYSTEM 238 Installation Manual

Alpha Keypad Programming

Start Programming the Keypad

[Installer Combination] [*] [0] [1] [#]

Alpha Keypad Test

[*] [6] [7] [#]

Kill/Revive Panel

[Installer Combination] [*] [6] [9] [#]

Panel Programming

Start Programming the Panel

[Installer Combination] [*] [0] [#]

Function

       Comments

Keystroke Sequence

The following Keypad Commands are Installer Only Commands:

Keypad  Operation  Command  Summary

The majority of the keypad commands apply equally to the LED and Alpha II keypads.  Some keypad commands, however, apply
to the LCD keypad only.

The following Keypad Commands apply to both the LED and Alpha II keypads:

Function

  Comments

Keystroke Sequence

Arm/Disarm

Delays active

[Combination] [#]

Bypass Zone (n)

[n] is zone # 1 - 8; Combo may be required

[Combination] [Bypass] [n] [#]

Chime On/Off

Combo may be required

[Combination] [*] [5] [#]

Change Combo (via

Must be done by User #1

[Master Combo] [*] [0] [#]

Master Code)

[New Combo] [#] [New Combo] [#]

Clear Alarm Memory

[*] [1] [#]

Exit Programming

[*] [#]

Fire Alarm

Keypad activated

[F] (Hold for 3 seconds)

Group Bypass and Arm

Arms system and all zones programmed for

[Combination] [*] [4] [#]

group bypass, CL 30 - 3F, Digit Position (3),
are shunted simultaneously; Combo may be
required. (Also called Home Arming)

Group Bypass and Instant

Same as Group Bypass (above) except system

[Combination] [*] [4] [7] [#]  or

Arm

is Instant Armed (Exit Delay operates normally,

[Combination] [*] [7] [4] [#]

upon expiration of Exit Delay, all delayed zones
are converted to Instant - No Entry Delay.
Combo may be required.  (Also called
Instant/Home Arming)

Instant Arm

Arms system and delayed zones are converted

[Combination] [*] [7] [#]

to Instant (Exit Delay active, No Entry Delay);
Combo may be required

Keypad Activated RPS

If enabled, CL 0B(3); Combo may be required

[Combination] [*] [0] [2] [#]

Medical Alarm

Keypad activated

[E] (Hold for 3 seconds)

Police/Panic Alarm

Keypad activated

[P] (Hold for 3 seconds)

Reset Aux Power

If resettable devices are connected to

[*] [6] [2] [#]

Terminals 5 and 6 (also resets devices
connected to Loop 8 (e.g. 2-wire smoke
detectors)

Reset Panel

[Master Combination] [*] [6] [8] [#]

Test - Battery

Use after correcting Low Battery problem

[*] [6] [4] [#]

Test - Bells

Combo may be required

[Combination] [*] [6] [3] [#]

Test - Central Station

Combo may be required

[Combination] [*] [6] [1] [#]

Test - Local Walk Test

[*] [6] [0] [#]

NOTE:  For additional information about Combination Command requirements, see page 24 and CL 09 (2).

Error Tones Toggle On/Off

[*] [5] [4] [#]

Audible Feedback Toggle

[*] [5] [1] [#]

Backlight Toggle On/Off

[*] [8] [#]

Display Keypad Model

[*] [9] [#]

& Revision Number

Chime Toggle

[*] [5] [3] [#]

Pre-warn Toggle On/Off

[*] [5] [2] [#]

Function

Comments

Keystroke Sequence

The following Keypad Commands apply to the Alpha II keypad only:

Содержание System 238

Страница 1: ...ort 2 5 8 5 VDC normal 8 6 15 VDC open Install transformer on unswitched power receptacle Only use 12 VDC 6 5 AH sealed lead acid battery POWER SUPPLY INFORMATION Replace battery every 3 5 years with...

Страница 2: ...han 45 seconds 7 No Exit Delay may be greater than 60 seconds 8 The Dynamic Battery Test must be enabled 9 The Unit Status Report must be enabled 10 The 24 hour Check in must be enabled 11 No Delay Be...

Страница 3: ...STEM 238 is capable of addressing up to 8 Alpha keypads LED keypads do not require addressing Each LED keypad uses 35 mA of current Each LCD keypad uses 64 mA of current See Available Power for curren...

Страница 4: ...structed in order to accommodate two switches One tamper for the cover and a second switch for a wall tamper To install the tamper switches Tamper Switches installed in the SYSTEM 238 cabinet LEAD ACI...

Страница 5: ...dows EOL circuit Zone 4 doors or windows EOL circuit Zone 5 interior EOL circuit Zone 6 interior EOL circuit Zone 7 24 hour panic or tamper EOL circuit Zone 8 fire or smoke supervised EOL circuit Emer...

Страница 6: ...owed by the key Then enter the data to be stored and again press the key Warning If you enter a Command Location and then press the key without entering any program data the keypad will beep 5 times i...

Страница 7: ...ess the programming mode when the control panel is disarmed NOTE Programming the Keypad is not the same as Keypad Programming 1 2 3 4 5 6 7 8 9 0 ALPHA II Programming Template ALPHA PLUS Programming T...

Страница 8: ...Arm and Disarm with O C Reports No Shunting 7 Arm Only No Closing Report Shunting Allowed 8 Disarm Only No Opening Report Shunting Allowed 9 Arm and Disarm No O C Reports Shunting Allowed 0 Arm Only...

Страница 9: ...eceiver 1 Message Format 1 3 1 single 2 3 1 extended 3 4 2 2 digit reporting code 4 4 1 5 CFSK III 6 4 9 Ademco DTMF 7 4 2 SumCheck 5 CFSK III 6 DTMF 1400 Hz 3 SumCheck 1400 Hz 4 SumCheck 2300 Hz 1 Fa...

Страница 10: ...rings with long pauses between rings 1 Double ring rings twice quickly followed by a long pause then rings twice again Digit Position 6 Dialing Attempts 5 5 tries 6 6 tries 7 7 tries 8 8 tries 1 1 tr...

Страница 11: ...he zeroes will not be dialed Command Location 0E Receiver 1 Phone Number digits 7 12 0 E 1 2 3 4 5 6 0 0 0 0 0 0 Default Values Command Location 0F Receiver 1 Phone Number digits 13 18 0 F 1 2 3 4 5 6...

Страница 12: ...Fill in remaining positions with 0 The zeroes will not be dialed 6 Order in which the numbers will be dialed 0 9 dialing digits 0 dial tone detect 2 DTMF dialing only not used in pulse dialing 3 DTMF...

Страница 13: ...be dialed Fill in remaining positions with 0 The zeroes will not be dialed 0 9 dialing digits 0 dial tone detect 2 DTMF dialing only not used in pulse dialing 3 DTMF dialing only not used in pulse dia...

Страница 14: ...conds 1 250 milliseconds 2 500 milliseconds 3 750 milliseconds Digit Position 3 Loop Restore Type 0 No Restoral Report sent 1 Restoral sent when loop normal 2 Restoral sent when loop normal and bell s...

Страница 15: ...ne Report Code Command Location 29 Soft Zone C Police Digit Positions 1 and 2 Police Report Code 1 2 3 4 0 0 1 2 Default Values 2 9 Digit Position 3 Police Zone Receiver Select Digit Position 4 Police...

Страница 16: ...ng options 1 Low battery 2 AC fail 3 Bell fuse fail 4 Loop trouble 5 Failed to communicate 6 Battery restore UNIT STATUS FIXED EXTENSION CODES 7 AC restore 8 Bell fuse restore 9 Loop trouble restore A...

Страница 17: ...s Report Code Valid entries are 0 F The User ID will be reported as the second digit when reporting in the 3 1 Extended 4 2 or CFSK formats Program 0 to disable Duress Reports Default Values 1 2 3 4 5...

Страница 18: ...efault Values 1 2 3 4 5 1 0 0 0 1 2 E Command Location 2F Unit Control Digit Position 1 Local System Only Default Values 1 2 3 4 0 0 1 1 2 F Digit Position 2 Enable Daily Dynamic Battery Test Digit Po...

Страница 19: ...g on alarm for time programmed in 0B 1 Command Location A0 Set Test Report Countdown Timer Digit Position 1 Set Countdown Timer A 0 1 0 1 4 hour 1 1 2 hour 2 1 hour 3 2 hours 4 3 hours 5 4 hours 6 6 h...

Страница 20: ...quipment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc tions may cause harmful interference to radio communications...

Страница 21: ...roup Bypass and Instant Same as Group Bypass above except system Combination 4 7 or Arm is Instant Armed Exit Delay operates normally Combination 7 4 upon expiration of Exit Delay all delayed zones ar...

Страница 22: ...exadecimal values are entered through the use of the key and one of the digits 0 5 For additional help with entering hexadecimal numbers refer to page 7 The hexadecimal conversion chart is also found...

Страница 23: ...two keypads are trying to communicate at the same time The only way to correct the problem is to disconnect both keypads and then re address one of them making sure that the address is not used by an...

Страница 24: ...It acts Time as a buffer on the loop to minimize the possibility of fast acting sensors such as swingers on window foil producing false alarms Loop Control 1F 26 3 Loop Restore This option is used in...

Страница 25: ...riod of four Power Up minutes after power is initially applied to the panel This allows Delay the sensors such as PIR s time to stabilize when initializing or prevents powered devices such as smoke de...

Страница 26: ...unction with the alarm system may not sense fires that start where smoke cannot reach the detectors such as chimneys walls or roofs or on the other side of closed doors Smoke detectors also may not se...

Страница 27: ...ate Control Location Installer Address VOLTS AC volts term 1 and 2 AUX POWER VOLTS term 5 and 6 CURRENT Keypads term 6 and 8 SWITCHED AUX term 5 and 6 UNSWITCHED AUX term 6 and 7 LOOP 8 POWERED DEVICE...

Страница 28: ...witches 3 1 0 1 0 0 Loop 2 Switches 3 3 0 1 0 0 Loop 4 Switches 3 5 0 1 0 0 Loop 6 Switches 3 7 0 0 0 0 Loop 8 Switches 1 1 A 1 D 2 A 1 Event Reports 2 C B 1 C 1 1 1 0 0 0 2 E Opening Closing Reports...

Отзывы: