SYSTEM 238 Installation Manual
14
Command Locations 17 - 1E: Loop Reporting Codes
17 = Loop 1
18 = Loop 2
19 = Loop 3
1A = Loop 4
Digit Positions (1) & (2): Alarm Reporting Code
Digit Positions (3) & (4): Restore Reporting Code
Digit Positions (5) & (6): Shunt Reporting Code
Only Position (1) is sent for 3/1 and 4/1 formats.
Positions (1) and (2) are sent for 3/1 Extended , 4/2, and CFSK formats.
Program 00 to disable Event Reporting for a loop.
If using 3/1 or 4/1 format, fill unused positions with "0".
(1)
(2)
(3)
(4)
(5)
(6)
1
0
E
1
0
0
7
1
**Default Values
1B = Loop 5
1C = Loop 6
1D = Loop 7
1E = Loop 8
Command Locations 1F - 26: Loop Control
1
2
1
3
2
3
F
1
**Default Values
(1)
(2)
(3)
(4)
(5)
(6)
1F = Loop 1
20 = Loop 2
21 = Loop 3
22 = Loop 4
23 = Loop 5
24 = Loop 6
25 = Loop 7
26 = Loop 8
Digit Position (1): Alarm Receiver Select
0 = Receiver 1 with Receiver 2 as back-up
1 = Receiver 1 only
2 = Receiver 2 only
3 = Receiver 1 and Receiver 2 (Dual Reporting)
Digit Position (2): Loop Response Time
0 = 5 milliseconds
1 = 250 milliseconds
2 = 500 milliseconds
3 = 750 milliseconds
Digit Position (3): Loop Restore Type
0 = No Restoral Report sent
1 = Restoral sent when loop normal
2 = Restoral sent when loop normal and bell silences
3 = Restoral sent when loop normal and system disarmed
Digit Position (4): Loop Arming Type
1 = Interior: delayed during E/E delays
2 = Instant
3 = Delay
4 = Long Delay: delay two times as long
5 = Day/Instant: buzzer on day fault
6 = Day/Delay: buzzer on day fault
7 = Day/Instant with bell
8 = Day/Delay with bell
9 = 24 Hours: always armed
Digit Position (5): Loop Bell Type
1 = Pulsing
2 = Steady
3 = Chirp
4 = Silent with no LED
5 = Silent with LED
Digit Position (6): Loop CircuitType
PROGRAMMING CONVERSIONS
Hexadecimal Value
Key Strokes
A
B
C
D
E
F
0
1
2
3
4
5
**Default Values are different
for each loop. Refer to the
SYSTEM 238 Programming
Worksheet at the end of this
manual.
#
#
NOTE:
A Loop programmed as type 4 or 5 will report
any open as a Trouble condition, regardless
of panel armed status.
1 = Normally Open Circuit
2 = Normally Closed Circuit
3 = End Of Line (EOL)
4 = Supervised, bell latched
5 = Supervised, bell not latched
Command Locations 17 - 26