SYSTEM 238 Installation Manual
20
KEYPAD LABEL DRAWER
Each keypad comes with a Label Drawer and quick reference operat-
ing label. Follow the diagram below to set up the Label Drawer for each
Example of drawer pulled
from the left
Example of drawer pulled
from the right
Regular maintenance and inspection (at least monthly) by the installer
and frequent testing by the user are vital to the continuous and
satisfying operation of any alarm system. The installer should assume
the responsibility for developing and offering a regular maintenance
program to the user, as well as acquainting the user with the proper
operation and limitations of the alarm system and its component parts.
Recommendations must include a specific program of regular
testing (at least weekly) to insure that the system is operating
properly at all times.
TELEPHONE LINE PROBLEMS
In the event of telephone line problems, disconnect the SYSTEM 238
by removing the modular connector plug from the Telco interface jack.
Do not disconnect the connection inside the SYSTEM 238 cabinet.
Doing so will prevent the premise phones from operating. If your phone
works correctly after the control panel has been disconnected from the
phone line, the control panel has a problem and should be returned for
repair.
If the phone does not work after you have disconnected the control
panel from the phone line, notify the telephone company and request
prompt repair. The user may not under any circumstance (in or out
of warranty) attempt any service or repairs on the SYSTEM 238.
The control panel must be returned to C&K SYSTEMS or an authorized
service agency for repairs.
DS1
WATCH
DOG
Watchdog Indicator
The SYSTEM 238 is protected by an advanced
circuit, called a Watch Dog circuit, that constantly
monitors the microprocessor.
As long as the panel has power and is operating
normally, the Watch Dog LED (DS1) on the circuit
board will flash. If the Watchdog circuit detects a failure, it will attempt
to reset the panel.
This equipment has been tested and found to comply with the limits for
a Class B digital devices, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
WARNING:
This device is intended to be installed by a
professional alarm installer.
The user shall be cautioned that changes or
modifications not expressly approved by C&K
SYSTEMS could void the user's authority to
operate the equipment.
This equipment generates, uses, and can radiate radio frequency
energy, and if not installed and used in accordance with the instruc-
tions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
.
Re-orient the radio/television antenna.
Connect the AC transformer to a different outlet so that the
control panel and radio/television are on different branch circuits.
.
Relocate the control panel with respect to the radio/television.
.
Consult the dealer or an experienced radio/television technician
for help.
.
In accordance with Part 68 of the FCC Rules, this device must not be
used on party lines or coin operated phone lines.
If you experience trouble with the telephone lines, disconnect the panel
from the line to determine the source of the trouble. If it is determined
that the control panel is malfunctioning, discontinue its use until the
malfunction has been corrected.
This digital apparatus does not exceed the Class B limits for radio noise
emmissions from digital apparatus set out in the Radio Interference
Regulations of the Canadian Department of Communications.
Le présent appariel numérique n'émet pas de bruits radioélectriques
dépassant les limites applicables aux appareils numériques de la
Class B prescrites dans le Règlement sur le brouillage radioélectrique
édicté par le ministère des Communications du Canada.
CANADIAN EMISSION REQUIREMENTS
FCC NOTICE
KEYPAD PLASTIC BASE
Rotate keypad base so
drawer slot faces the correct direction
Plastic
drawer
Plastic drawer and label slide into
drawer on back of keypad base
Plastic drawer
1. Fill in the zone descriptions inside the label.
2. Mark "Y" or "N" to indicate if zones can be bypassed or not.
3. Determine if the drawer will slide from the right or left.
4. Peel the cover off the drawer glue.
5. Align the edge of the label with the edge of the drawer. Center
the label top to bottom.
6. Press the label onto the glue. Avoid trapping air bubbles under
the label.
7. Slide the drawer/label into the slot on the back of the keypad
base.
TESTING
Once the installation is complete, connect AC and DC power. Com-
plete programming, if required. Test all panel operations.
TO THE INSTALLER
If the panel does not operate properly, and the Watchdog LED no
longer flashes, call the C&K Technical Support Hotline at 1-800-
227-8065 in the U.S. or your local C&K Representative.