The four black distance gauges are for use with the 1.5mm and 3 mm spots only.
There are two types of distance gauges for each spot size and they are labeled on the
support leg similar to the amber distance gauges. Each spot size has a small and large
distance gauge with either a small or large treatment ring at the end. The large ring
offers increased visibility when the treatment area is relatively flat. The small ring
works better when the treatment area is on a curved surface or in close proximity to
protrusions.
The 3 mm distance gauge is inserted and removed from the handpiece using the same
technique as for the amber distance gauges. The 3 mm distance gauge does not have a
window in it. This is because the procedures associated with this spot size deliver less
energy to the treatment area and create much less debris. Note that there is a window
at the end of the 1.5/3 mm slider to keep the lenses in it clean. Figures 1.4 and 1.5
show the two types of 3 mm distance gauges.
The 1.5 mm distance gauge is significantly different from all the other distance
gauges. This distance gauge contains a lens and a window to help keep the lens
clean. Care must be used when handling this distance gauge to ensure that the lens
remains clean. The recommended method of holding the 1.5 mm distance gauge is by
grasping it firmly on the support leg. Figures 1.6 and 1.7 show the two types of 1.5
mm distance gauges
Содержание GentleYAG
Страница 1: ...Operator s Manual 0123 8501 00 1766 Revision F June 2006 ...
Страница 4: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 4 ...
Страница 48: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 48 ...
Страница 125: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 125 Labeling Symbols Section 7 ...
Страница 133: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 133 Label 13 ...
Страница 137: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 137 5 A B C 6 ...
Страница 144: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 144 ...
Страница 145: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 145 Accessory List Section 8 ...
Страница 150: ...GentleYAG Laser System Candela Corporation 8501 00 1766 Revision F CONFIDENTIAL Page 150 ...