CANAM TECHNOLOGY, INC. (CTI)
MARK-IV UHF NARROWBAND SIGNAL BOOSTER
OPERATIONS & MAINTENANCE (O&M) MANUAL
Page 29 of 36
Rev0 June/2011
This page shows meters and the different alarms. The auto-refresh radio-
button allows periodic page updates every 5 seconds approximately.
Summary Alarm
Master Summary alarm Indicator. Green if no single
alarm is present in the system, Red otherwise.
SNMP Agent
Shows the SNMP Agent current status (It is disable for
this model).
MCPA’s Meters and Status
Status
Indicates if the MCPA Output is “Unmuted”,
“Muted” or “Muted by Alarm”(in case the MCPA
Reflected Power Alarm is “Triggered” or
“Latched” and the option “Enable Automatic Mute
upon Reflected Power Alarm” has been selected in
Main Settings
page).
Output Power (dBm)
Composite Output Power.
The Status will be “Undetermined” when the power
is not readable; “Normal” when it is above the
threshold and “Triggered” if it is below the
threshold.
Reflected Power
(dBm)
Composite Reflected Power.
The Status will be “Normal” when it is below the
threshold; “Triggered” if it is above the threshold
and “Latched” when a previous Reflected Power
Alarm has not been cleared.
Current Drain Idc (A)
Power Amplifier DC current drain.
The Status indicator will be green when the current
is within the operating levels, red otherwise.
Temperature (ºC)
Power Amplifier heat-sink temperature.
The Status indicator will be green when the
temperature is within the operating levels, red
otherwise.