o
Actual Maximum Desired Output (Set-point) <= Lowest Rx
Thr 120dB.
THUS: The User entered Set-point may be automatically reduced
to meet the maximum 120dB Gain. For example, this will happen
if the User reduces an Rx Threshold setting below the lowest
previously defined.
o
The Desired Output (Set-point) values are limited by this
constraint.
o
NOTE: This equation is driven by the lowest Rx Threshold value in
the filters bank, i.e. if at least one filter is set lower than the rest,
that value drives the output Set-Point for the entire bank.
Press the “Apply” button to apply changes to the current state. The current
state applied to system is saved to the controller’s internal nonvolatile
memory for effective recovery after a power loss or system reset.
Pilot Test Carrier:
Turn on/off the pilot test carrier which is related to first channel at current first
channel frequency.