WARRANTY 

GENERAL 

Camus Hydronics Limited (“Camus”) extends the following LIMITED WARRANTY to the owner of this appliance, 
provided that the product has been installed and operated in accordance with the Installation Manual provided with 
the equipment. Camus will furnish a replacement for, or at Camus option repair, any part that within the period 
specified below, shall fail in normal use and service at its original installation location due to any defect in 
workmanship, material or design. The repaired or replacement part will be warranted for only the unexpired portion of 
the original warranty. This warranty does not cover failures or malfunctions resulting from: (1) Failure to properly 
install, operate or maintain the equipment in accordance with Camus’ manual; (2) Abuse, alteration, accident, fire, 
flood, foundation problems and the like; (3) Sediment or lime buildup, freezing, or other conditions causing 
inadequate water circulation; (4) Pitting and erosion caused by high water velocity; (5) Failure of connected systems 
devices, such as pump or controller; (6) Use of non-factory authorized accessories or other components in 
conjunction with the system; (7) failing to eliminate air from, or replenish water in, the connected water system; (8) 
Chemical contamination of combustion air or use of chemical additives to water. 

HEAT EXCHANGER 

If within TEN years after initial installation of the appliance, a heat exchanger shall prove upon examination by Camus 
to be defective in material or workmanship, Camus will exchange or repair such part or portion on the following pro 
rated limited warranty. (1) Years one through five - standard warranty (2) Years six through ten - replacement 
purchase price pro rated at the following schedule: Year six - 60%, Year seven - 65%, Year eight -70%, Year nine -
75% Year ten -80% of the current list price of the current list price This term is reduced to FIVE years if the appliance 
is used for other than hydronic space heating. 
Heat Exchanger shall be warranted for (20) years from date of installation against “Thermal Shock” (excluded, 
however, if caused by appliance operation at large changes exceeding 150 ºF between the water temperature at 
intake and appliance temperature, or operating at appliance temperatures exceeding 230 ºF). 

BURNER 

If within ONE year after initial installation of the appliance a burner shall prove upon examination by Camus to be 
defective in material or workmanship, Camus will exchange or repair such part or portion. 

ANY OTHER PART 

If any other part fails within one (1) year after installation, or eighteen (18) months from date of factory shipment 
based on Camus' records, whichever comes first. Camus will furnish a replacement or repair that part. Replacement 
parts will be shipped f.o.b. our factory. 

HOW TO MAKE A CLAIM 

Any claim under this warranty shall be made directly to Camus Hydronics Limited Canadian Head Office 

SERVICE LABOR RESPONSIBILITY 

Camus shall not be responsible for any labour expenses to service, repair or replace the components supplied. Such 
costs are the responsibility of the owner. 

DISCLAIMERS 

Camus shall not be responsible for any water damage. Provisions should be made that in the event of a 
water/appliance or fitting leak, the resulting flow of water will not cause damage to its surroundings. 

 

 
Name of Owner 

 

 
Name of Dealer 

 

 
Address 

 

 
Address 

 

 
 

 

 

 

 
Model No. 

 

 
Serial No. 

 

 
Date of Installation: 

 

 
Date of Initial Operation: 

 

6226 Netherhart Road, Mississauga, Ontario, L5T 1B7, CANADA 

Содержание BLUE-FLAME Series

Страница 1: ...nce WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance o Do not touch any electrical switch do not use any phone in your building o Immediately call your gas supplier from a neighbour s p...

Страница 2: ...9 WARNING REGARDING CHILLED WATER SYSTEMS 8 10 PIPING OF BOILER TO THE SYSTEM FIG 3 8 11 PLACING BOILER IN OPERATION 10 12 CHECK OUT OF IGNITION SYSTEM SAFETY SHUT OFF DEVICE 10 13 LOW WATER TEMPERAT...

Страница 3: ...by the authority having jurisdiction the installation must conform to the Standard for Controls and Safety Devices for Automatically Fired Boilers ANSI ASME CSD 1 The qualified installer shall instru...

Страница 4: ...to combustibles as follows TOP 12 SIDES 12 REAR 12 VENT 6 3 PROVIDE AIR FOR COMBUSTION AND VENTILATION Provisions for combustion and ventilation air must be in accordance with section 5 3 Air for comb...

Страница 5: ...ff and remote controller use terminal strip provided inside control panel Refer to wiring diagram provided with boiler 5 GAS SUPPLY AND PIPING This boiler is intended to operate at inlet gas pressures...

Страница 6: ...installations always consider the use of a shelter such as a garden shed in lieu of direct exposure of the appliance to the elements The additional protection afforded by the shelter will help to min...

Страница 7: ...ove return doors windows exhaust fans fireplace dampers and any other gas burning appliance to their previous condition of use g Any improper operation of the common venting system must be corrected s...

Страница 8: ...6 Three venting options are available for this boiler See Figure 1 below for details Standard Venting Outdoor Venting Sidewall Venting Side View Figure 1...

Страница 9: ...relief valve sized in accordance with ASME Boiler and Pressure Vessel Code Section IV Heating Boilers The relief valve is to be installed in the vertical position and mounted in the hot water outlet N...

Страница 10: ...means to prevent gravity circulation of chilled water through the boiler Chilled water in the boiler will create condensate on the boiler tubes which will collect in the combustion chamber causing co...

Страница 11: ...tion level it must be provided with a low water cutoff device at the time of boiler installation Available from factory To eliminate trapped air install venting devices at high points in the system as...

Страница 12: ...ter level in expansion tank If level exceeds of tank volume air is still trapped in system Shut down boiler and continue to run pumps Within 3 days of start up recheck all air vents and expansion tank...

Страница 13: ...e after 15 minutes c If the inlet temperature is less than 110 F slowly close outlet valve until the inlet temperature climbs to 110 F d If the inlet temperature is greater than 110 F but not greater...

Страница 14: ...ns Figure 5 15 PILOT AND MAIN BURNER FLAMES To maintain safe operation and the greatest efficiency of the boiler check the main burner and pilot burner every six months for proper flame characteristic...

Страница 15: ...off power and close main manual gas valve Allow burners to cool before removal 2 Loosen union and remove main burner tray assembly from boiler 3 Remove and thoroughly clean burners Check all ports and...

Страница 16: ...e ignition electrode using sandpaper Once the pilot appears to be properly set reinstall it into the boiler making sure to properly tighten the pilot line connection Once the spark is satisfactory ope...

Страница 17: ...tion 15 of this manual After the first season of operation inspect the heat exchanger and venting Follow the detailed instructions in section 6 of this manual CAUTION Label all wires prior to disconne...

Страница 18: ...ime to light the pilot if air is not present in the pilot line If pilot fails to light and you suspect air in the line close the main manual valve and repeat lighting steps 1 thru 5 7 Once the pilot l...

Страница 19: ...lame Adjust if necessary Remove pilot and ensure that spark electrode is clean and properly located 5 Pilot lights but main burner does not fire Ensure that main firing valve is in OPEN position Check...

Страница 20: ...CAL DIAGRAMS Each Blue Flame boiler will be provided with its own wiring diagram to guarantee that any options ordered with the unit are properly detailed The following diagrams 99 5020 and 99 5021 ar...

Страница 21: ...19...

Страница 22: ...20...

Страница 23: ...21 21 EXPLODED VIEW...

Страница 24: ...22 22 BLUE FLAME REPLACEMENT PARTS LIST...

Страница 25: ...standard warranty 2 Years six through ten replacement purchase price pro rated at the following schedule Year six 60 Year seven 65 Year eight 70 Year nine 75 Year ten 80 of the current list price of...

Страница 26: ...uilt water heaters and heating boilers as well as a into every single unit For more information supplier of specialty HVAC products Our service line is open 24 hours 7 days a week on our innovative pr...

Отзывы: