21
H - POSSIBLE PROBLEMS / cORREcTIVE AcTION
Possible problems
Probable causes / corrective action
The burner does not light up
• Poor gas supply
• regulator not operating properly
• Pipe, valve, venturi tube or burner holes obstructed
• Clean the venturi
The burner does not burn smoothly or goes
out
• Check that gas is present
• Check the pipe connection
• Contact your servicing agent."
Unstable blowing flames
• New cylinder may contain air. Allow the appliance to operate and
the fault will clear itself
• Residual water, following the washing of the burner caps
• Contact your servicing agent.
Large plume of flame on the burner surface
• The venturi is obstructed (possibly cobwebs)
• Contact your servicing agent."
Flame at the injector
• The cylinder is almost empty
• Change the cylinder and the fault will clear itself
• Contact your servicing agent.
Burning leak around a union
• Shut off the gas supply immediately
• Leaking union: tighten nuts or change pipe
• Contact your servicing agent.
Insufficient heat
• Injector or venturi tube obstructed
• Contact your servicing agent.
• Clean the venturi
Burning leak behind the adjustment knob
• Defective valve
• Shut down the stove
• Contact your servicing agent.
I - WARANTY PERIOD
Years
2
GB
• If the appliance will not be used for a long period of time, disconnect the cylinder as indicated in section § F.
• Regularly check the condition of the hose and change it if it shows signs of ageing or cracking (see section § C-2).
• In the case of the injector becoming clogged (the cylinder still contains gas but the appliance will not light), do not try
to unclog it yourself. Return the appliance to your retailer.