SECTION 11. OUTPUT PROCESSING INSTRUCTIONS
11-2
There are three Output Options that specify the
values calculated.
Option 0:
Mean horizontal wind speed, S.
Unit vector mean wind direction,
Θ
1.
Standard deviation of wind direction,
σ
(
Θ
1).
Standard deviation is calculated using the
Yamartino algorithm. This option complies
with EPA guidelines for use with straight-
line Gaussian dispersion models to model
plume transport.
Option 1:
Mean horizontal wind speed,
S
.
Unit vector mean wind direction,
Θ
1.
Option 2:
Mean horizontal wind speed,
S.
Resultant mean wind speed, U.
Resultant mean wind direction,
Θ
u.
Standard deviation of wind direction,
σ
(
Θ
u).
This standard deviation is calculated using
Campbell Scientific's wind speed weighted
algorithm.
Use of the Resultant mean horizontal wind
direction is not recommended for straight-
line Gaussian dispersion models, but may
be used to model transport direction in a
variable-trajectory model.
Measured raw data:
S
i
= horizontal wind speed
Θ
i
= horizontal wind direction
Ue
i
= east-west component of wind
Un
i
= north-south component of wind
N = number of samples
Calculations:
Scalar mean horizontal wind speed, S:
S=(
Σ
S
i
)/N
where in the case of orthogonal sensors:
S
i
=(Ue
i
2
+Uni
2
)
1/2
Unit vector mean wind direction,
Θ
1:
Θ
1=Arctan (Ux/Uy)
where
Ux=(
Σ
sin
Θ
i
)/N
Uy=(
Σ
cos
Θ
i
)/N
or, in the case of orthogonal sensors
Ux=(
Σ
(Ue
i
/U
i
))/N
Uy=(
Σ
(Un
i
/U
i
))/N
where U
i
=(Ue
i
2
+Un
i
2
)
1/2
Standard deviation of wind direction,
σσσσ
(
Θ
Θ
Θ
Θ
1)
,
using Yamartino algorithm:
σ
(
Θ
1)=arc sin(
ε
)[1+0.1547
ε
3
]
where,
ε
=[1-((Ux)
2
+(Uy)
2
)]
1/2
and Ux and Uy are as defined above.
Resultant mean horizontal wind speed, U:
U=(Ue
2
+Un
2
)
1/2
where for polar sensors:
Ue=(
Σ
S
i
Sin
Θ
i
)/N
Un=(
Σ
S
i
Cos
Θ
i
)/N
or, in the case of orthogonal sensors:
Ue=(
Σ
Ue
i
)/N
Un=(
Σ
Un
i
)/N
Resultant mean wind direction,
Θ
Θ
Θ
Θ
u:
Θ
u=Arctan (Ue/Un)
Standard deviation of wind direction,
σσσσ
(
Θ
Θ
Θ
Θ
u)
,
using Campbell Scientific algorithm:
σ
(
Θ
u)=81(1-U/S)
1/2
*** 70 SAMPLE ***
FUNCTION
This instruction stores the value from each
specified input location. The value(s) stored are
those in the input location(s) when Instruction
70 is executed with the Output Flag set high.
PARAM.
DATA
NUMBER
TYPE
DESCRIPTION
01:
4
Repetitions
02:
4
Starting input location no.
Outputs Generated:
1 for each repetition
Содержание CR510
Страница 1: ...CR510 DATALOGGER OPERATOR S MANUAL REVISION 2 03 COPYRIGHT c 1986 2003 CAMPBELL SCIENTIFIC INC ...
Страница 2: ...This is a blank page ...
Страница 4: ...This is a blank page ...
Страница 10: ...This is a blank page ...
Страница 44: ...SECTION 1 FUNCTIONAL MODES 1 14 This is a blank page ...
Страница 56: ...SECTION 3 INSTRUCTION SET BASICS 3 8 ...
Страница 104: ...SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES 8 8 This is a blank page ...
Страница 128: ...SECTION 10 PROCESSING INSTRUCTIONS 10 8 This is a blank page ...
Страница 144: ...SECTION 12 PROGRAM CONTROL INSTRUCTIONS 12 10 This is a blank page ...
Страница 172: ...SECTION 14 INSTALLATION AND MAINTENANCE 14 10 This is a blank page ...
Страница 176: ...APPENDIX A GLOSSARY A 4 This is a blank page ...
Страница 184: ...This is a blank page ...
Страница 188: ...APPENDIX D DATALOGGER INITIATED COMMUNICATIONS D 4 This is a blank page ...
Страница 196: ...APPENDIX F MODBUS ON THE CR10 X AND CR510 F 4 This is a blank page ...
Страница 197: ...APPENDIX G TD OPERATING SYSTEM ADDENDUM FOR CR510 CR10X AND CR23X MANUALS ...
Страница 198: ...This is a blank page ...
Страница 200: ...This is a blank page ...
Страница 206: ...TABLE DATA ADDENDUM AD 6 This is a blank page ...
Страница 222: ...TD ADDENDUM SECTION 1 FUNCTIONAL MODES AD 1 8 This is a blank page ...
Страница 238: ...TD ADDENDUM SECTION 8 PROCESSING AND PROGRAM CONTROL EXAMPLES AD 8 10 This is a blank page ...
Страница 240: ...This is a blank page ...