Appendix A.  Wireless Ace Setup without Template File 

!

 

S23 – Configure Serial Port – The baud rate needs to be configured to 
match a valid datalogger  baud rate. For a CR10X: 9600,8N1 and for a 
CR1000: 115200,8N1. 

!

 

\Q – Serial Port Flow Control – This should be set to None. 

!

 

V – AT Verbose Mode – Set this to Numeric. 

!

 

&D – DTR Mode – Set to Ignore DTR 

!

 

S211 – DTR Mode – Set to Ignore DTR 

 

A-2 

Содержание Airlink Raven

Страница 1: ...INSTRUCTION MANUAL Copyright 2008 Campbell Scientific Canada Corp Raven EDGE GPRS EDGE Airlink Cellular Modem March 2008...

Страница 2: ...glect accidents of nature or shipping damage This warranty is in lieu of all other warranties expressed or implied including warranties of merchantability or fitness for a particular purpose CSC is no...

Страница 3: ...irements for Raven EDGE 2 4 2 Datalogger Site Equipment 2 4 3 Power Considerations 6 5 Program the Raven EDGE Modem 6 5 1 Using ACE Manager to Configure the Modem 7 5 2 Dynamic IP Address 10 6 LoggerN...

Страница 4: ...4 4 2 2 Antennas for Use with the Raven Modems 6 7 1 Wireless Ace status page showing communications with modem 17 B 1 Modem Back B 1 B 2 Modem Partially Slid from Case B 1 B 3 Tray Button B 2 B 4 Emp...

Страница 5: ...the Internet A Dynamic IP address is assigned on a need to have basis A dynamic IP address is used with a service such as IP Manager Section 5 to translate a dynamic IP address to a domain name so th...

Страница 6: ...o 250 mA Typical Current Drain at 12 Vdc 20 mA dormant connection idle for 10 to 20 seconds 130 mA transmit receive Operating Temperature Range 30 to 70 C 10 duty cycle limit above 60 C Operating Humi...

Страница 7: ...not Rev 1 or newer as indicated on cable it is a CS I O cable only and will not work for RS 232 Connect the black SC12 cable between the datalogger and the SC932A Use a 9 pin serial cable or a blue r...

Страница 8: ...gers with the PakBus Operating System SC932A interface connects the modem to the CS I O port recommended for dataloggers with the Mixed Array Operating System PN 18663 null modem cable connects the mo...

Страница 9: ...n diameter o The L14454 9dBd Yagi Antenna is a higher gain antenna that should be aimed at the service provider s antenna The L14454 includes 10 feet of cable fitted with a TNC male connector for atta...

Страница 10: ...ENC 16 18 4 3 Power Considerations A power cable included with the modem connects to the datalogger s 12 V or switched 12 V terminal Connection to the switched 12 V terminal allows the datalogger to...

Страница 11: ...rs that support a maximum baud rate of 9600 e g CR10X The template file configures the modem to be compatible with CSI dataloggers The template files are available from Campbell Scientific s Website w...

Страница 12: ...lick OK to continue Click the Load icon in the Configuration panel When prompted for a template file name select ravengprs_115200 xml for dataloggers that support 115200 baud e g CR1000 or ravengprs_9...

Страница 13: ...ate supported by the datalogger e g 115200 for a CR1000 NOTE Click on EDGE HSDPA Group to get the following screen A Rogers account with VPN com is configured for an Access Point Name APN VPN com Ente...

Страница 14: ...ust also Reset the modem before the changes will take effect NOTE 5 2 Dynamic IP Address Data Plan accounts setup through Rogers are provided with a Dynamic IP address Dynamic IP addresses are granted...

Страница 15: ...gerNet PC400W Toolbar Configure the Device Map as described below 1 Select Add Root IPPort 2 Add a datalogger to the IPPort PakBus dataloggers e g the CR1000 require a PakBusPort 3 On the IPPort page...

Страница 16: ...Raven EDGE GPRS EDGE AirLink Cellular Modem Preceding zeros are not entered in the Internet IP Address e g 070 218 074 247 is entered as 70 218 74 247 NOTE 12...

Страница 17: ...a Dynamic Domain Name Server DDNS Section 5 The modem has to be configured using ACE Manager as described in Section 5 Modem settings have to be changed and the APN number entered using ACE Manager Se...

Страница 18: ...irLink Cellular Modem The Device Port gets changed from the default 12345 to 6785 when the template file is loaded into the modem Section 5 The Device Port number gets entered with the IP address in L...

Страница 19: ...y the datalogger e g 115200 baud for the CR1000 If an SC105 interface is used its default baud rate of 9600 will have to be changed to match the baud rate of the modem using CSI s DevConfig utility Ba...

Страница 20: ...evice Map The IP address and Device Port settings are entered in LoggerNet as described in Section 6 Make sure the port number at the end of the IP address matches the port number of the modem The tem...

Страница 21: ...the response from the datalogger did not make it back to the modem Check the interface between the modem and the datalogger If both values incremented the modem and the datalogger are communicating T...

Страница 22: ...Raven EDGE GPRS EDGE AirLink Cellular Modem 18 This is a blank page...

Страница 23: ...p www campbellsci ca download html The procedure for sending the template files is described in Section 5 When the template files are not available ACE Manager can be used to change the settings descr...

Страница 24: ...he baud rate needs to be configured to match a valid datalogger baud rate For a CR10X 9600 8N1 and for a CR1000 115200 8N1 Q Serial Port Flow Control This should be set to None V AT Verbose Mode Set t...

Страница 25: ...Appendix A Wireless Ace Setup without Template File S0 TCP Auto Answer Set to On TCPT TCP Idle Timeout Set to a reasonable value like 2 min A 3...

Страница 26: ...Appendix A Wireless Ace Setup without Template File A 4 This is a blank page...

Страница 27: ...M To install the SIM you will only need a small phillips head screw driver Opening the Case 1 Unplug the modem power and all cables 2 Using a small phillips head screw driver remove the two screws on...

Страница 28: ...y SIM Tray Inserting the SIM 6 Place the SIM into the tray and gently press to click it into place FIGURE B 5 SIM Tray with a SIM 7 Slide the tray back into the modem and gently press to click it into...

Страница 29: ...the datalogger PPP enables the datalogger to send receive messages via email HTTP FTP to and from the datalogger and allows concurrent communications between networked dataloggers and LoggerNet The de...

Страница 30: ...r PPP Use ACE Manager to configure the following PPP settings HOSTPRIVMODE 0 HOSTPRIVIP 192 168 1 1 Use WirelessAce to configure the following UDP setting MD 02 PPP Use AceManager to configure the fol...

Страница 31: ...on to save the changes in the modem Click the Reset icon to restart the modem The other ways to reset the modem are by pressing the reset button on the front of the modem or removing the power from th...

Страница 32: ...ect the Net Services tab The PakBus TCP Service Port default is 6785 This is the Port number that will follow the IP address for LoggerNet to communicate with the datalogger Using the Device Configura...

Страница 33: ...Appendix C Configuring the Raven for PPP LoggerNet Settings Enter the IP address of the Raven and the PakBus TCP Service Port number of the datalogger e g 6785 as explained above C 5...

Страница 34: ...RLF CHR 13 CHR 10 Public Result as String 100 Public AlarmTrigger As Boolean Public Message As String 250 Public EmailSuccess As Boolean BeginProg Scan 1 Sec 3 0 Battery Batt PanelTemp RefTemp 250 TCD...

Страница 35: ...Appendix C Configuring the Raven for PPP C 7 This is a blank page...

Отзывы: