Operating Instructions

www.chpower.com

Introduction

Refer to Figure 5 to locate the following 
items.

pressure Switch -

 Auto/Off Switch - In 

the "

aUtO

" position, the compressor 

shuts off automatically when tank 
pressure reaches the maximum preset 
pressure. In the "

OFF

" position, the 

compressor will not operate. This switch 
should be in the "

OFF

" position when 

connecting or disconnecting the power 
cord from the electrical outlet.

regulator -

 The regulator controls 

the amount of air pressure at the hose 
outlet.

aSMe Safety valve -

 This valve 

automatically releases air if the tank 
pressure exceeds the preset maximum.

exhaust tube -

 This tube carries 

compressed air from the pump to the 
check valve. This tube becomes very hot 
during use. To avoid the risk of severe 
burns, never touch the discharge tube.

Check valve -

 One-way valve that 

allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.

Handle -

 Designed to move the 

compressor.

 

Never use the  

  handle on wheeled 

units to lift the unit completely off the 
ground.

Drain valve -

 This valve is located on 

the bottom of the tank. Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion.

pressure Gauges

 - These gauges will 

show air pressure in the compressor 
tank and at the compressor outlet.

Outlet pressure Gauge

 - Will show 

air pressure at the outlet in pounds per 
square inch (psi). Make sure this gauge 
reads ZERO (by adjusting regulator 
knob fully counterclockwise) before 
changing air tools or disconnecting air 
hose from outlet.

tank pressure Gauge

 - Will show air 

pressure in tank while the compressor 
is running, indicating compressor 
is building pressure properly. This 
gauge will show maximum pressure 
of compressor when it shuts off 
automatically at the pressure switch.

Motor reset

 - (not shown, located 

inside motor). Designed to keep the 
motor from overheating. The motor has 
an auto reset protector. To reset once 
the motor has cooled, turn the pressuer 
switch to the OFF position, then to the 
AUTO position.

 

This compressor is  

  equipped with an 

overload protector which will shut off 
motor if it becomes overloaded.
 

If the overload  

  protector is 

actuated, the motor must be allowed 
to cool down for approximately 30 
minutes before it will reset.

Installation

LOCatIOn

It is extremely important to install the 
compressor in a clean, dry, and well 
ventilated area. The compressor must 
be placed on a firm, level surface where 
the surrounding air temperature will 
not be more than 100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.

 

Do not locate the  

  compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.

eLeCtrICaL InStaLLatIOn 

 

All wiring   

  and 

electrical connections should 
be performed by a qualified 
electrician. Installation must 
be in accordance with local codes and 
national electrical codes.

WIrInG

1.  Local electrical wiring codes 

differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum.

2.  Use a slow blow fuse or a circuit 

breaker.

3.  This product is for use on a nominal 

120 volt circuit and has a grounding 
plug that looks like the plug 
illustrated in Figure 7. Make sure the 
product is connected to an outlet 
having the same configuration 
as the plug. This product must 
be grounded. In the event of an 
electrical short circuit, grounding 
reduces risk of electrical shock by 
providing an escape wire for electric 
current. This product is equipped 
with a cord having a grounding 
wire with an appropriate grounding 
plug. Plug must be plugged into an 
outlet that is properly installed and 
grounded in accordance with all 
local codes and ordinances.

 

Overheating, short  

  circuiting and fire 

damage will result from inadequate 
wiring.

TEST

RESET

Figure 7 - Grounding Method

Grounded Outlet

Grounding Pin

Figure 6 - auto / Off Switch

Minimum Gauge of extension Cord

25 ft.

50 ft.

100 ft.

14

12

10

Use of an extension cord may cause excess 
heat to motor. This could lead to tripped 
breaker (at electrical panel) or tripped 
thermal overload (on compressor motor). 
If this occurs, eliminate extension cord and 
plug compressor directly into electrical 
outlet. Avoid using extension cords; use 
longer air hose(s) instead.

Содержание IN630101AV

Страница 1: ...nstructions Do Not Discard Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed m...

Страница 2: ...n cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the compressor C...

Страница 3: ...Figure 4 Lubrication This unit is shipped without oil Follow lubrication instructions before operating compressor Use oil shipped with the compressor Do not use regular automotive oil such as 10W 30...

Страница 4: ...motor if it becomes overloaded If the overload protector is actuated the motor must be allowed to cool down for approximately 30 minutes before it will reset Installation Location It is extremely impo...

Страница 5: ...used ASME Safety Valve Do not remove or attempt to adjust the safety valve Check the safety valve by performing the following steps 1 Plug the compressor in and run until shut off pressure is reached...

Страница 6: ...aining tank 5 Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain 6 Compressor and hose should be stored in a cool dry place Technical Service For in...

Страница 7: ..._________________________ ________________________________________________________________________________________________ _____________________________________________________________________________...

Страница 8: ...off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain va...

Страница 9: ...filter 2 Clean or replace filter 3 Circuit overloaded 3 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 4...

Страница 10: ...re caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rus...

Страница 11: ...UCTIONS CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Recher...

Страница 12: ...ctriques peuvent causer des arcs lectriques qui peuvent allumer un gaz ou une vapeur inflammable Ne jamais utiliser ou r parer le mod le pr s d un gaz ou d une vapeur inflammable Ne jamais entreposer...

Страница 13: ...veau max sur le regard Le niveau d huile appropri est illustr la Figure 3 FILTRE D ASPIRATION Enfiler le filtre d aspiration dans l ouverture filet e sur le c t de la t te du compresseur tel qu illust...

Страница 14: ...n limite R initialisation du moteur non illustr se trouve l int rieur du moteur Con u pour emp cher le moteur de surchauffer Le moteur a un protecteur de r initialisation automatique Pour r initialise...

Страница 15: ...Inspecter le compresseur souvent et suivre les proc d s d entretien suivants pendant chaque utilisation du compresseur SOUPAPE DE S RET ASME Ne jamais enlever ni essayer d ajuster la soupape de s ret...

Страница 16: ...eau de la soupape de s curit l aide de l autre main d tourner l air se d pla ant rapidement pour prot ger le visage 4 Vidanger le r servoir de toute condensation en ouvrant le robinet de vidange au fo...

Страница 17: ...__________________ ________________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 18: ...se coupe 1 Raccordements d gag s raccords tuyaux etc 1 V rifier tous les raccordements avec de l eau savonneuse Resserrer ou retirer et appliquer aux filets un produit scellant ou de ruban pour filets...

Страница 19: ...fusible utiliser un fusible retardement D brancher les autres appareils lectriques du circuit ou faire fonctionner le compresseur sur un circuit r serv 4 Utilisation de rallonge Calibre inad quat de...

Страница 20: ...nt pas d effet sur le fonctionnement du compresseur d Les r servoirs rouill s y compris mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composa...

Страница 21: ...TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministramos...

Страница 22: ...ompresor cerca de gases o vapores inflamables Nunca almacene l quidos o gases inflamables cerca del compresor Las piezas del compresor podr an estar calientes inclusive cuando la unidad est apagada 9...

Страница 23: ...e aceite est ilustrado en la Figura 3 Filtro de entrada Enrosque el filtro de entrada de aire en la abertura roscada que se encuentra en uno de los lados del cabezal del compresor seg n se ilustra en...

Страница 24: ...Para reiniciar una vez que se haya enfriado el motor coloque el interruptor en la posici n de apagado OFF y luego en la posici n de autom tico AUTO Este compresor est equipado con un protector de sobr...

Страница 25: ...Enchufe el compresor y h galo funcionar hasta que se alcance la presi n de corte consulte Funcionamiento 2 Usando gafas de protecci n tire del anillo de la v lvula de seguridad para liberar la presi...

Страница 26: ...ue halando el anillo de la v lvula de seguridad Use su otra mano para desviar el aire que se mueve a gran velocidad y evitar que le d en el rostro 4 Drene el tanque de la condensaci n abriendo la v lv...

Страница 27: ...__________________ ________________________________________________________________________________________________ ____________________________________________________________________________________...

Страница 28: ...aja cuando el compresor se apaga 1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para roscas lue...

Страница 29: ...i rese de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 4 Uso del cable de extens...

Страница 30: ...ncionamiento del compresor d Tanques oxidados incluyendo pero no limitado al xido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art culos sujet...

Страница 31: ...Notes Notas 31 Operating Instructions Instructions d Utilisation Manual de Instrucciones HL5401 HX5400 Series...

Страница 32: ...ucciones HL5401 HX5400 Series Date Maintenance Performed Repair Components Required Date Entretien Ex cut l ments de Remplacement Requis Fecha Maintenimiento Efectuado Componentes de Reparaci n Necesa...

Отзывы: