manualshive.com logo in svg
background image

Pressure switch

 - Auto/Off Switch - In 

the 

aUtO

 position, the compressor 

shuts off automatically when tank 
pressure reaches the maximum preset 
pressure. In the 

OFF

 position, the 

compressor will not operate. This switch 
should be in the 

OFF

 position when 

connecting or disconnecting the power 
cord from the electrical outlet or when 
changing air tools.

Regulator

 - The regulator controls 

the amount of air pressure at the 
hose outlet. Turning regulator knob 
clockwise (to the right) will increase  air 
pressure at the outlet. Turning knob 
counterclockwise (to the left) will lower 
air pressure to the outlet. Turning knob 
fully counterclockwise will shut off flow 
of air completely. 

asMe safety valve

 - This valve is 

attached to the pressure switch. It will 
automatically releases air if the tank 
pressure exceeds the preset maximum.

exhaust tube

 - This tube carries 

compressed air from the pump to the 
check valve. This tube becomes very hot 
during use. To avoid the risk of severe 
burns, never touch the exhaust tube.

Check valve

  - This valve is located at 

the end of the exhaust tube where it 
meets the tank. It is a one-way valve 
that allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.

handle

 - Designed to move the 

compressor.

 

Never use the 

  handle on wheeled 

units to lift the unit completely off the 
ground.

Drain valve

 - This valve is located on 

the bottom of the tank. Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion.

Pressure Gauges

 - These gauges will 

show air pressure in the compressor 
tank and at the compressor outlet.

3

hL5403, hL5404

Glossary of terms

Outlet Pressure Gauge

 - Will show 

air pressure at the outlet in pounds per 
square inch (psi). Make sure this gauge 
reads ZERO (by adjusting regulator 
knob fully counterclockwise) before 
changing air tools or disconnecting air 
hose from outlet.

tank Pressure Gauge

 - Will show air 

pressure in tank while the compressor 
is running, indicating compressor 
is building pressure properly. This 
gauge will show maximum pressure 
of compressor when it shuts off 
automatically at the pressure switch.

Motor Reset

 - (not shown, located 

inside motor). Designed to keep the 
motor from overheating. The motor has 
an auto reset protector. To reset once 
the motor has cooled, turn the pressuer 
switch to the OFF position, then to the 
AUTO position.

 

This compressor is  

  equipped with an 

overload protector which will shut off 
motor if it becomes overloaded.
 

If the overload  

  protector is 

actuated, the motor must be allowed 
to cool down for approximately 30 
minutes before it will reset.

Installation

LOCatIOn

It is extremely important to install the 
compressor in a clean, dry, and well 
ventilated area. The compressor must 
be placed on a firm, level surface where 
the surrounding air temperature will 
not be more than 100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.

 

Do not locate the 

  compressor air inlet 

near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.

eLeCtRICaL InstaLLatIOn 

 

All wiring and   

  electrical 

connections should be performed by a 
qualified electrician. Installation must 
be in accordance with local codes and 
national electrical codes.

Handle

Outlet 

Pressure 

Gauge

Exhaust 

Tube

Oil Sight 
Gauge

Oil Drain Plug

Air Filter

Regulator

Tank Pressure 
Gauge

Pressure Switch

Figure 1 - Unit Identification

Содержание HL5404

Страница 1: ...ions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions...

Страница 2: ...inspect compressed air system and electrical components for signs of damage deterioration weakness or leakage Repair or replace defective items before using 8 Check all fasteners at frequent intervals...

Страница 3: ...f Terms Outlet Pressure Gauge Will show air pressure at the outlet in pounds per square inch psi Make sure this gauge reads ZERO by adjusting regulator knob fully counterclockwise before changing air...

Страница 4: ...ing oil gradually and checking the oil level with the sight glass several times Add enough oil to reach the max level on the sight glass Proper oil level is illustrated in Figure 3 Operation Before fi...

Страница 5: ...warm up oil Unplug unit 2 Position a pan under pump end of unit 3 Remove drain plug see Figure 1 Allow oil to collect in pan Tilt unit to completely drain 4 Replace drain plug fill pump to center of...

Страница 6: ...and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain valve 2 Close tank drain valve 3 Tank leaks 3 Check tank for leaks with soap and...

Страница 7: ...3 Circuit overloaded 3 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 4 Extension cord usage wrong gauge...

Страница 8: ...ial number if any 100 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Operating Instructions and Parts Manual Figure 7 Replacement Parts Illustration for Oi...

Страница 9: ...ut out 95 psi cut in HL031000AV 1 21a Unloader valve not shown CW212400AV 1 22 Check valve HL030500AV 1 23 Plug ST022500AV 1 24 Straight tube fitting HL035900AV n 1 Ref Part No Description No Qty Ref...

Страница 10: ...any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Operating Instructions and Parts Manual Figure 8 Replacement Parts Illustratio...

Страница 11: ...g v 1 28 M5 x 10 Drain plug v 1 29 O ring m 1 30 Breather m 1 31 Crankcase cover gasket 6 1 32 Crankcase 1 33 M5 Washer 4 34 M5 X 16 Shroud screw 4 35 Oil seal 1 Ref Part No Description No Qty Ref Par...

Страница 12: ...contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limited to rust due to improper drainage or corrosive environments e The following...

Страница 13: ...ssembler installer faire fonctionner ou entretenir l appareil d crit Prot gez vous et les autres en observant toutes les informations sur la s curit N gliger d appliquer ces instructions peut r sulter...

Страница 14: ...nt l utilisation de la pompe ou de l appareil 6 Ne pas se tenir debout ni utiliser la pompe ou l appareil comme une prise 7 Inspecter le syst me d air comprim et pi ces d tach es lectriques pour toute...

Страница 15: ...Con ue pour le d placement du compresseur Ne jamais utiliser la poign e sur les mod les avec roues pour soulever l appareil Ne jamais utiliser la poign e sur les mod les avec roues pour soulever le mo...

Страница 16: ...le niveau se trouve au centre du regard d huile viter de remplir excessivement en ajutant l huile graduellement et en v rifiant plusieurs fois le niveau d huile dans le regard Ajouter la quantit d hu...

Страница 17: ...e bout de la pompe du mod le 3 Enlever le bouchon de vidange permettre que l huile se vide dans le r cipient Voir Figure 1 Incliner l appareil pour le vider compl tement 4 Replacer le bouchon de purge...

Страница 18: ...seur se coupe 1 Raccordements d gag s raccords tuyaux etc 1 V rifier tous les raccordements avec de l eau savonneuse Resserrer ou retirer et appliquer aux filets un produit scellant ou de ruban pour f...

Страница 19: ...ancher les autres appareils lectriques du circuit ou faire fonctionner le compresseur sur un circuit r serv 4 Utilisation de rallonge Calibre inad quat de la rallonge et ou rallonge trop longue 4 Reti...

Страница 20: ...800 543 6400 S il vous pla t fournir l information suivante Adresser toute correspondance Num ro de Mod le Attn Customer Service Num ro de s rie si pr sent 100 Production Drive Description et num ro...

Страница 21: ...0AV 1 21a Soupape de d chargement non illustr CW212400AV 1 22 Clapet HL030500AV 1 23 Bouchon ST022500AV 1 24 Raccord de tube droit HL035900AV n 1 N de N de r f Description pi ce Qt 25 Virole u 2 26 cr...

Страница 22: ...il vous pla t fournir l information suivante Adresser toute correspondance Num ro de Mod le Campbell Hausfeld Num ro de s rie si pr sent Attn Customer Service Description et num ro de la pi ce 100 Pr...

Страница 23: ...1 30 Reniflard m 1 31 Joint d tanch it du couvercle de carter 6 1 32 Carter 1 33 M5 Rondelle 4 34 M5 X 16 Vis de couvercle de protection 4 35 Bague d tanch it d huile 1 N de N de r f Description pi c...

Страница 24: ...ais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e Les composants suivants sont consid r s comme des articles sujets l usure normale et ne sont pas cou...

Страница 25: ...adosamente antes de tratar de montar instalar operar o dar mantenimiento al producto aqu descrito Prot jase usted mismo y a los dem s observando toda la informaci n de seguridad El no cumplir con las...

Страница 26: ...us manos despu s de usar Cuando corta lija taladra o pule materiales como por ejemplo madera pintura metal hormig n cemento u otro tipo de mamposter a se puede producir polvo Con frecuencia este polvo...

Страница 27: ...mpresor Nunca use el mango de las unidades con ruedas para levantar completamente la unidad Llave de drenaje Esta v lvula est ubicada debajo del tanque sela para drenar la humedad del tanque diaria me...

Страница 28: ...icando el nivel de aceite varias veces por medio del visor de vidrio Agregue suficiente aceite para que llegue al nivel marcado con max en el visor de vidrio El nivel adecuado de aceite est ilustrado...

Страница 29: ...xtremo del cabezal 3 Desconecte la unidad del tomacorrientes Vea la Figura1 Qu tele el tap n del orificio de lubricaci n y vierta el aceite dentro del recipiente Vire un poco la unidad para drenar el...

Страница 30: ...que baja cuando el compresor se apaga 1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para rosca...

Страница 31: ...i rese de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 4 Uso del cable de extens...

Страница 32: ...s Cercano a Su Domicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Attn Customer Service C digo impreso 100 Production Drive Descripci n y n mero del...

Страница 33: ...n a 655 0 kPa 95 psi HL031000AV 1 21a V lvula de descarga no se muestra CW212400AV 1 22 V lvula de chequeo HL030500AV 1 23 Tap n ST022500AV 1 24 Accesorio de tubo recto HL035900AV n 1 No de No de Ref...

Страница 34: ...omicilio Sirvase darnos la siguiente informaci n Dirija toda la correspondencia a N mero del modelo Campbell Hausfeld C digo impreso Attn Customer Service Descripci n y n mero del repuesto seg n la li...

Страница 35: ...espiradero m 1 31 Junta de la tapa de la caja del cig e al 6 1 32 Caja del cig e al 1 33 M5 Arandela 4 34 M5 X 16 Tornillo de la cubierta 4 35 Sello del sistema de lubricaci n 1 No de No de Ref Descri...

Страница 36: ...do pero no limitado al xido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art culos sujetos a desgaste normal y no son cubiertas despu s del pr...

Отзывы: