3

2. If repair or replacement of cord or

plug is necessary, do not connect
grounding wire to either flat blade
terminal. The wire with insulation
having an external surface that is
green (with or without yellow
stripes) is the grounding wire.

Never

connect green (or green and yellow) wire
to a live terminal.

3. Check with a qualified electrician or

serviceman if grounding instructions
are not completely understood, or if
in doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.

Overheating, short circuiting and fire
damage will result from inadequate
wiring, etc.

Operation

Definition of Terms

ON / OFF Switch ( I / O )

- Push switch

to the ON ( 

I

) position to turn

compressor on. Push switch to the OFF 

O

) position to turn compressor off.

This switch should be in the OFF (

O

)

position when connecting /
disconnecting power cord from
electrical outlet or when changing tools.

Pressure Switch (located internally)

-

When the compressor is turned ON,
this switch will shut compressor off
automatically when tank pressure
reaches maximum shut-off / cut-out
pressure. If compressor remains on and
air is depleted from tank, this switch
will allow compressor to automatically
restart at the restart / cut-in pressure.

Regulator

- The regulator controls the

amount of air pressure released at the
hose outlet. Turning the regulator knob
clockwise (to the right) will increase air
pressure at the outlet. Turning the knob
counter-clockwise (to the left) will
lower air pressure to the outlet. Turning
knob fully counter-clockwise will shut
off flow of air completely.

Pressure Gauges

- There are two

gauges located next to the regulator.
These gauges read air pressure in
pounds per square inch (psi) The larger
gauge shows pressure at the outlet.
Make sure this gauge reads ZERO (by
adjusting the regulator) BEFORE
changing air tools or disconnecting hose
from outlet. The small gauge shows
pressure in the tank indicating
compressor is building pressure properly. 

ASME Safety Valve

- This valve

automatically releases air if the tank
pressure exceeds the preset maximum.

Handle 

- Designed to move the

compressor.

Drain Valve

- This valve is located on

the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.

Motor Reset - 

(not shown, located

inside motor). Designed to keep the
motor from overheating. The motor
has an auto reset protector. To reset
once the motor has cooled, turn the
switch to the OFF position, then to the
ON position.

This

compressor is equipped with an overload
protector which will shut off motor if it
becomes overloaded.

If the

overload protector is actuated, the motor
must be allowed to cool down for
approximately 30 minutes before it will
reset.

LUBRICATION

This is an oilless product and 

DOES

NOT

require lubrication to operate.

BEFORE FIRST STARTUP
BREAK-IN PROCEDURE

(Complete this procedure before using
compressor for the first time. Once
completed, it is not necessary to repeat.)
1. Turn regulator knob fully clockwise

(to the right) to open air flow.

2. Do not attach a hose or any other

fitting to the compressor.

3. Turn on/off switch to OFF position.

4. Plug in power cord.

5. Turn on/off switch to ON position.

Allow compressor to run for 5
minutes.

6. Turn on/off switch to OFF position.

ON/OFF Switch

Drain Valve

Figure 2 - Unit Identification

Handle

Pressure

Gauges

Safety Valve

Air Outlet

Regulator

OFF Position

Figure 3

ON Position

Figure 4

Installation 

(Continued)

Содержание FP2090 Series

Страница 1: ...MAY cause damage to equipment CALIFORNIA PROPOSITION 65 This product or its power cord contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm...

Страница 2: ...iodically for unsafe conditions such as rust formation and corrosion 14 Fast moving air will stir up dust and debris which may be harmful Release air slowly when draining moisture or depressurizing th...

Страница 3: ...Pressure Gauges There are two gauges located next to the regulator These gauges read air pressure in pounds per square inch psi The larger gauge shows pressure at the outlet Make sure this gauge read...

Страница 4: ...underneath tank CLEANING Turn power OFF and clean dust and dirt from pump cover tank and air lines IMPORTANT Unit should be located as far from spraying area as hose will allow to prevent over spray...

Страница 5: ...exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated area where temperature wil...

Страница 6: ...E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or a...

Страница 7: ...OSITION 65 DE CALIFORNIE Ce produit ou son cordon contient des produits chimiques qui de l avis de l tat de Californie peut causer le cancer et des anomalies cong nitales ou autres probl mes de reprod...

Страница 8: ...ifier un r servoir Le soudage per age ou autre modifications peuvent affaiblir le r servoir et peuvent r sulter en dommage de rupture ou d explosion Toujours remplacer un r servoir us fendu ou endomma...

Страница 9: ...ettre en marche le compresseur Mettre l interrupteur la position OFF O pour teindre le compresseur Cet interrupteur devrait tre dans la position OFF O pendant le branchement ou le d branchement du cor...

Страница 10: ...et ensuite dissiper toute la pression du syst me avant d essayer d installer de r parer de d placer ou de proc der l entretien L entretien doit tre r alis seulement par un repr sentant de service aut...

Страница 11: ...Ou retirer le raccord et appliquer un ruban tuyau sur les filets puis remonter Ne pas d monter le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 V rifier tout le r servoir avec d...

Страница 12: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Страница 13: ...f brica para suministrarle aire respirable Antes de utilizarlos con este fin deber instalarle un sistema de seguridad y alarma incorporado a la l nea Este sistema adicional es necesario para filtrar...

Страница 14: ...ar las v lvulas de seguridad Igualmente debe evitar que se le acumule pintura u otros materiales Nunca trate de reparar o modificar el tanque Si lo suelda taladra o modifica de cualquier otra manera e...

Страница 15: ...ctar o desconectar el cord n el ctrico del tomacorrientes o para cambiar herramientas Interruptor de presi n ubicado internamente Al encender el compresor ON este interruptor lo apaga autom ticamente...

Страница 16: ...interruptor en OFF O desenchufe el cable el ctrico y drene el aire del tanque Mantenimiento Desconecte el cord n el ctrico del tomacorrientes y libere toda la presi n del sistema antes de tratar de i...

Страница 17: ...osici n OFF O apagado 2 Desenchufe el cord n del tomacorrientes de pared y envu lvalo alrededor del mango para prevenir da os cuando no se use 3 Con las gafas de seguridad puestas descargue el aire de...

Страница 18: ...Verifique todas las conexiones el ctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presi n 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor a un rea limpia y bien ve...

Страница 19: ...onales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en l...

Страница 20: ...Notes Notes Notas FP2090 FP2091 FP2094 20 Oilless Compressors Compresseur Sans Huile Compresores Sin Aceite...

Отзывы: