manualshive.com logo in svg
background image

2

Oilless Compressors

General Safety
Information

Since the air compressor and other
components used (filters, lubricators,
hoses, etc.), make up a high pressure
pumping system, the following safety
precautions must be observed at all times:

1. Read all manuals included

with this product carefully.
Be thoroughly familiar with
the controls and the proper
use of the equipment.

2. Follow all local electrical and safety

codes as well as in the US, National
Electrical Codes (NEC) and Occupational
Safety and Health Act (OSHA).

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the compressor.

4. Keep visitors away and NEVER allow

children in the work area.

5. Wear safety glasses and

use hearing protection
when operating the
pump or unit.

6. Do not stand on or use the pump or

unit as a handhold.

7. Before each use, inspect compressed

air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.

8. Check all fasteners at frequent

intervals for proper tightness.

Motors, electrical equipment
and controls can cause
electrical arcs that will ignite
a flammable gas or vapor. Never
operate or repair in or near a
flammable gas or vapor. Never store
flammable liquids or gases in the
vicinity of the compressor.

Compressor parts may be hot
even if the unit is stopped.

9. Keep fingers away from a running

compressor; fast moving and hot
parts will cause injury and/or burns.

10. If the equipment should start to

abnormally vibrate, STOP the
engine/motor and check
immediately for the cause. Vibration
is generally a warning of trouble.

11. To reduce fire hazard, keep

engine/motor exterior free of oil,
solvent, or excessive grease.

Never

remove or

attempt to adjust safety valve. Keep
safety valve free from paint and other
accumulations.

Never attempt to repair or
modify a tank! Welding,
drilling or any other
modification will weaken the tank
resulting in damage from rupture or
explosion. Always replace worn or
damaged tanks.

Drain liquid from tank daily.

13. Tanks rust from moisture build-up,

which weakens the tank. Make sure
to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and corrosion.

14. Fast moving air will stir up dust and

debris which may be harmful. Release
air slowly when draining moisture or
depressurizing the compressor system.

SPRAYING PRECAUTIONS

Do not spray flammable
materials in vicinity of open
flame or near ignition
sources including the compressor unit.

15. Do not smoke when spraying paint,

insecticides, or other flammable
substances.

16. Use a face mask/

respirator when spraying
and spray in a well
ventilated area to prevent
health and fire hazards.

17. Do not direct paint or other sprayed

material at the compressor. Locate
compressor as far away from the
spraying area as possible to
minimize overspray accumulation
on the compressor.

18. When spraying or cleaning with

solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.

HOSE PRECAUTIONS

19. Inspect hose before use.

Do not exceed working
pressure marked on hose.

Do not

twist, bend knot, or abrade hose.

20. Do not wrap hose around body.

Keep

away from hot surfaces and chemicals.

Installation

LOCATION

It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than 100°F.

A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could
obstruct air flow.

Do not

locate the

compressor air inlet near steam, paint
spray, sandblast areas or any other
source of contamination. This debris
will damage the motor.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Figure 1. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.

Improper use of grounding
plug can result in a possible
risk of electrical shock!

Do not

use a

grounding adapter with this product!

TEST

RESET

Figure 1 - Grounding Method

Grounding

Pin

Grounded Outlet

MANUAL

Содержание FP2090 Series

Страница 1: ...MAY cause damage to equipment CALIFORNIA PROPOSITION 65 This product or its power cord contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm...

Страница 2: ...iodically for unsafe conditions such as rust formation and corrosion 14 Fast moving air will stir up dust and debris which may be harmful Release air slowly when draining moisture or depressurizing th...

Страница 3: ...Pressure Gauges There are two gauges located next to the regulator These gauges read air pressure in pounds per square inch psi The larger gauge shows pressure at the outlet Make sure this gauge read...

Страница 4: ...underneath tank CLEANING Turn power OFF and clean dust and dirt from pump cover tank and air lines IMPORTANT Unit should be located as far from spraying area as hose will allow to prevent over spray...

Страница 5: ...exceed 100 F 5 Check all electrical connections 6 Replace ON OFF switch 7 Replace pressure switch 8 Replace pump motor assembly 1 Move compressor to a clean well ventilated area where temperature wil...

Страница 6: ...E Items or service that are normally required to maintain the product e g lubricants filters and gaskets etc F Additional items not covered under this warranty 1 Any component damaged in shipment or a...

Страница 7: ...OSITION 65 DE CALIFORNIE Ce produit ou son cordon contient des produits chimiques qui de l avis de l tat de Californie peut causer le cancer et des anomalies cong nitales ou autres probl mes de reprod...

Страница 8: ...ifier un r servoir Le soudage per age ou autre modifications peuvent affaiblir le r servoir et peuvent r sulter en dommage de rupture ou d explosion Toujours remplacer un r servoir us fendu ou endomma...

Страница 9: ...ettre en marche le compresseur Mettre l interrupteur la position OFF O pour teindre le compresseur Cet interrupteur devrait tre dans la position OFF O pendant le branchement ou le d branchement du cor...

Страница 10: ...et ensuite dissiper toute la pression du syst me avant d essayer d installer de r parer de d placer ou de proc der l entretien L entretien doit tre r alis seulement par un repr sentant de service aut...

Страница 11: ...Ou retirer le raccord et appliquer un ruban tuyau sur les filets puis remonter Ne pas d monter le clapet Avec de l air dans le r servoir purger le r servoir d abord 3 V rifier tout le r servoir avec d...

Страница 12: ...ints d tanch it s par exemples F Articles suppl mentaires qui ne sont pas couverts sous cette garantie 1 Toutes pi ces d tach es endommag es pendant l exp dition n importe quelle panne caus e par un m...

Страница 13: ...f brica para suministrarle aire respirable Antes de utilizarlos con este fin deber instalarle un sistema de seguridad y alarma incorporado a la l nea Este sistema adicional es necesario para filtrar...

Страница 14: ...ar las v lvulas de seguridad Igualmente debe evitar que se le acumule pintura u otros materiales Nunca trate de reparar o modificar el tanque Si lo suelda taladra o modifica de cualquier otra manera e...

Страница 15: ...ctar o desconectar el cord n el ctrico del tomacorrientes o para cambiar herramientas Interruptor de presi n ubicado internamente Al encender el compresor ON este interruptor lo apaga autom ticamente...

Страница 16: ...interruptor en OFF O desenchufe el cable el ctrico y drene el aire del tanque Mantenimiento Desconecte el cord n el ctrico del tomacorrientes y libere toda la presi n del sistema antes de tratar de i...

Страница 17: ...osici n OFF O apagado 2 Desenchufe el cord n del tomacorrientes de pared y envu lvalo alrededor del mango para prevenir da os cuando no se use 3 Con las gafas de seguridad puestas descargue el aire de...

Страница 18: ...Verifique todas las conexiones el ctricas 6 Reemplace el interruptor ON OFF 7 Cambie el interruptor de presi n 8 Reemplace el ensamble de la bomba motor 1 Mueva el compresor a un rea limpia y bien ve...

Страница 19: ...onales no cubiertos bajo esta garant a 1 Cualquier componente da ado durante el env o o cualquier da o ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en l...

Страница 20: ...Notes Notes Notas FP2090 FP2091 FP2094 20 Oilless Compressors Compresseur Sans Huile Compresores Sin Aceite...