K1 relay
or output module
Jumper W1
Terminal block J1
MC-II Flow Analyzer
Appendix B—Pulse Output Option, Intrinsically Safe
MC-II Pulse Output Circuit Assembly
(Part No. 100005163; Intrinsically Safe)
The pulse output circuit assembly (Figure B1) equips the MC-II Flow Analyzer to provide an optional pulse
output. It is mounted inside the unit between the totalizer board and the battery cavity.
Important—When this circuit assembly is installed according to Figures B2, B3 and B4 (pages 35 and
36), the MC-II with pulse output is rated by Canadian Standards Association as Intrinsically Safe for
Class I, Division 1, Groups A,B,C and D.
Pulse Input - Intrinsically Safe
The pulse input to this card is obtained from the “Pulse Out” of the totalizer card. It will appear in the form of
a square wave pulse.
Pulse Output - Intrinsically Safe
The pulse output from this card is provided in the form of a dry contact from a relay, transistor open-collector,
or an emitter/collector opto-isolated output. A 14-pin socket on the card is provided to install either the relay
or component plug “module”, whichever is specified.
Electrical Specifications - Intrinsically Safe
Current Required
10 mA
Relay Contact Rating
200 mA, 6 VDC
Open Collector Module
200 mA, 6 VDC
Opto-Isolated Module
100 mA, 6 VDC
Pulse Output Duration
60 msec (approx)
Figure B1—Pulse output circuit assembly, intrinsically safe (Part No. 100005163 / 991.44828)
35
Содержание NuFlo MC-II
Страница 1: ...NUFLO MC II FlowAnalyzer User Manual Manual No 100079666 Rev OE ...
Страница 6: ...MC II Flow Analyzer 2 Figure 1 Nomenclature exterior ...
Страница 7: ...MC II Flow Analyzer 3 Figure 2 Nomenclature interior ...
Страница 32: ...MC II Flow Analyzer 28 ...
Страница 35: ...Figure A2 Field wiring for dry contact pulse output option non hazardous areas MC II Flow Analyzer 31 ...
Страница 36: ...32 Figure A3 Field wiring for open collector pulse output option non hazardous areas MC II Flow Analyzer ...
Страница 37: ...Figure A4 Field wiring for opto isolated pulse output option non hazardous areas MC II Flow Analyzer 33 ...
Страница 38: ...MC II Flow Analyzer 34 ...
Страница 44: ...40 MC II Flow Analyzer ...
Страница 45: ......
Страница 46: ......