MC-II Flow Analyzer
29
Appendix A—Pulse Output Option, Non-Intrinsically Safe
MC-II Pulse Output Circuit Assembly
(Part No. 100005121; nonhazardous use)
The pulse output circuit assembly (Figure A1) equips the MC-II Flow Analyzer to provide an optional pulse
output. It is mounted inside the unit between the totalizer board and the battery.
WARNING: Do not use in hazardous areas.
Pulse Input
The pulse input to this card is obtained from the “Pulse Out” of the totalizer card. It will appear in the form of
a square wave pulse.
Pulse Output
The pulse output from this card is provided in the form of a dry contact from a relay, transistor open-collector,
or an emitter/collector opto-isolated output. A 14-pin socket on the card is provided to install either the relay
or component plug “module”, whichever is specified. The relay coil voltage must match the voltage of sup-
plied power. Relays are available in 5V, 12V, and 24V (listed in the spare parts list on page 27).
Electrical Specifications
Current Required
10 mA
Relay Contact Rating 0.5A, 30 VDC, 10W max (resistive)
Open Collector Module 0.3A max, 30 VDC max
Opto-Isolated Module 0.1A max, 30 VDC max
Pulse Output Duration 60 msec (typical)
K1 relay
or output module
Jumper W1
Terminal block J1
Figure A1—Pulse output circuit assembly (Part No. 100005121 / 991.43450)
!
Содержание NuFlo MC-II
Страница 1: ...NUFLO MC II FlowAnalyzer User Manual Manual No 100079666 Rev OE ...
Страница 6: ...MC II Flow Analyzer 2 Figure 1 Nomenclature exterior ...
Страница 7: ...MC II Flow Analyzer 3 Figure 2 Nomenclature interior ...
Страница 32: ...MC II Flow Analyzer 28 ...
Страница 35: ...Figure A2 Field wiring for dry contact pulse output option non hazardous areas MC II Flow Analyzer 31 ...
Страница 36: ...32 Figure A3 Field wiring for open collector pulse output option non hazardous areas MC II Flow Analyzer ...
Страница 37: ...Figure A4 Field wiring for opto isolated pulse output option non hazardous areas MC II Flow Analyzer 33 ...
Страница 38: ...MC II Flow Analyzer 34 ...
Страница 44: ...40 MC II Flow Analyzer ...
Страница 45: ......
Страница 46: ......