K11208a;19/36
- 19 -
MS=1 SS=7
MS=1 SS=7
ID: CAMERA-1
FC1600FCL
ID not specified
ID specified
FC1600FCL
[VX.XX]
Menu display of Setting Group 2
MENU2
MENU
: ON
-
: (Reserved)
-
: (Reserved)
PWC
: DISABLED
MS=A SS=7
MF=0008.0000
GAIN:
The left number is the gain setting value expressed in the decimal system. (Range: 16 to 240).
When gain and offset set value coincides with preset value (four levels of preset value), “SET” followed by
corresponding preset No. is displayed on the right side.
OFFSET:
The set value of the digital signal offset is displayed in the decimal system. (Range: 32 to 224)
S.TIME:
The current shutter speed is displayed. The left number is H number (horizontal synchronous time unit, in
the case of high speed shutter – range: 1 to 1068 <normal scan> or range: 1 to 533 <partial scan> in
decimal system) or V number (vertical synchronous time unit, in the case of low speed shutter – range: 1 to
255 in decimal system). The right number in parentheses shows the actual time.
The actual time is displayed after being converted in accordance with the settings of the scan mode (all
pixels/partial) and shutter mode (HIGH/LOW).
(Note) When the pulse width control mode is set for the asynchronous shutter operation or when a shutter setting value is
out of the predetermined range in the partial scan mode, the actual time is displayed as “--.-”.
S.FORM:
The current shutter operation mode is displayed. The left is either
continuous (NORMAL) or asynchronous (ASYNC), and the right is
either high speed (HIGH) or low speed (LOW).
SCAN:
The current scanning system is displayed. It is either all pixel
readout scan (NORMAL) or partial readout scan (PARTIAL).
(
→
See “Priority relationship among scan mode setting items”
described in another section
PWC:
Whether the position “9” of the shutter switch for the asynchronous
shutter operation is used (ENABLED) or not used (DISABLED) is
selected.
BZ:
This is to switch between (ON) and (OFF) for the confirmation
sound to be activated when switch manipulation is made.
BAUD:
The baud rate used for RS-232C communication is displayed.
H-RESET: Whether the horizontal timing resetting(initialization) is enabled
or not enabled is selected. If it is enabled, H(horizontal
synchronization) timing is reset when the trigger signal is input
in the asynchronous shutter operation mode.
Vinit2:
The polarity of the trigger signal via CC1 of Camera Link is set.
The factory default is negative logic (NORMAL). When
(INVERTED) is selected, positive logic input is used.
STRB-C:
ON/OFF is set for the strobe signal (STRB) output for the
continuous shutter operation. When (ON) is selected, the
strobe signal is output even in the continuous shutter mode.
(Note) The strobe signal is always output in the asynchronous shutter mode
regardless of this setting.
PATTERN:
This is to switch between (ON) and (OFF) for the test pattern
output.
bit This is to switch between (8 bit) and (10 bit) for the bit rate of
image output.
* The following items are for display only; they cannot be directly changed
on the menu. These are automatically updated when a corresponding
change is made using the switches:
MS=
The current position of the mode switch is displayed.
SS=
The current position of the shutter setting switch (EXP.) is
displayed.
MF=
The information (16 bits x 2 sets) of the internal mode flags
of the camera (internal flags to determine operation) is displayed
in the hexadecimal system. The details of the internal flags are
described later.
Tc=
The current internal temperature of the camera is displayed in
Celsius. The temperature data are refreshed every 0.4 seconds.
FC1600FCL
[VX.XX]
Menu display of Setting Group C
MENU 3
MENU
: ON
BZ
: ON
BAUD
: 9600bps
-
: (Reserved)
H-RESET: DISABLED
:
Vinit 2
: NORMAL
STRB-C : OFF
MS=C SS=7
MF=0008.0000
FC1600FCL
[VX.XX]
Menu display of Setting Group D
MENU 4
MENU
: ON
PATTERN : OFF
bit
: 8bit
MS=C SS=7
MF=0008.0000