Menu 1st level
Menu 2nd level
Options
Default
Setting the starting slow-down of M2 before the closing limit-switch point, calcu-
lated as a percentage (from 1% to 60% of the full leaf-swing).
&
This function only appears if the
[Enc. Slodwn.] function is enabled
in the
[ENCODER] menu
.
[M1 CL. Appr. %] [1%]
……
[15%]
[15%]
Setting the starting latch-speed of M1 before the closing limit-switch point,
calculated as a percentage (from 1% to 15% of the full leaf-swing).
[M2 CL. Appr. %] [1%]
……
[15%]
[15%]
Setting the starting latch-speed of M2 before the closing limit-switch point,
calculated as a percentage (from 1% to 15% of the full leaf-swing).
[M1 Appr.CH %]
[1%]
……
[15%]
[15%]
Setting the starting latch-speed of M1 before the opening limit-switch point,
calculated as a percentage (from 1% to 15% of the full leaf-swing).
[M2 OP. Appr. %] [1%]
……
[15%]
[15%]
Setting the starting latch-speed of M2 before the opening limit-switch point,
calculated as a percentage (from 1% to 15% of the full leaf-swing).
[Calibrating
Swing]
[Confirm? (no)] / [Confirm? (yes)]
Automatic calibration of the gate-leaf swing (see the CALIBRATING SWING
paragraph).
[SET TIMES]
[A.C.T]
[0 s]
……
[300 s]
[10 s]
The wait before the automatic closing starts when the opening limit-switch point
is reached, and can be set to between 1 s and 300 s. The automatic closing does
not work if any of the safety devices trigger when an obstruction is detected, or
after a total stop, or during a power outage.
[Pedestrian ACT] [0 s]
……
[300 s]
[10 s]
Waiting time of M2's second leaf in the open position. Once this time elapses, the
shutter automatically closes. The waiting time can be set to between 0 and 300
seconds.
[Working Time]
function
[10 s]
……
[150 s]
[90 s]
Gearmotor working time during opening and closing. The working time can be set
to between 10 and 150 seconds.
[Op. Delay M1]
[0 s]
……
[10 s]
[2 s]
M1 opening delay with respect to M2 after each opening command. The waiting
time can be set to between 0 and 10 seconds.
[Cl. Delay M2]
[0 s]
……
[60 s]
[2 s]
M2's closing delay with respect to M1's closing after each closing command. The
waiting time can be set to between 0 and 60 seconds.
[Preflashing T]
[1 s]
……
[60 s]
[5 s]
After and opening or closing command, the flashing light connected to W-E,
flashes from between 1 and 60 seconds before starting the maneuver.
[Lock time]
[1 s]
……
[5 s]
[2 s]
Intervention time for the electrolock to release after each opening command. The
intervention time can be set to between one second and five seconds.
[Jolt time]
[1 s]
……
[10 s]
[1 s]
The closing and opening jolt thrust-time of the geartmotors after each command.
The thrust time can be set to between one and three seconds.
[Part.open]
[5 s]
……
[60 s]
[10 s]